CoChat

Theranostic Application of Mixed Gold and Superparamagnetic Iron Oxide Nanoparticle Micelles in Glioblastoma Multiforme

Open access
Sun, Lova, Joh, Daniel Y., Al-Zaki, Ajlan, Stangl, Melissa, Murty, Surya, Davis, James J., Baumann, Brian C., Alonso-Basanta, Michelle, Kao, Gary D., Tsourkas, Andrew, Dorsey, Jay F. · 2016 · Journal of Biomedical Nanotechnology
Cited by 119

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The treatment of glioblastoma multiforme, the most prevalent and lethal form of brain cancer in humans, has been limited in part by poor delivery of drugs through the blood-brain barrier and by unclear delineation of the extent of infiltrating tumor margins. Nanoparticles, which selectively accumulate in tumor tissue due to their leaky vasculature and the enhanced permeability and retention effect, have shown promise as both therapeutic and diagnostic agents for brain tumors. In particular, superparamagnetic iron oxide nanoparticles (SPIONs) have been leveraged as T2-weighted MRI contrast agents for tumor detection and imaging; and gold nanoparticles (AuNP) have been demonstrated as radiosensitizers capable of propagating electron and free radical-induced radiation damage to tumor cells. In this study, we investigated the potential applications of novel gold and SPION-loaded micelles (GSMs) coated by polyethylene glycol-polycaprolactone (PEG-PCL) polymer. By quantifying gh2ax DNA damage foci in glioblastoma cell lines, we tested the radiosensitizing efficacy of these GSMs, and found that GSM administration in conjunction with radiation therapy (RT) led to ~2-fold increase in density of double-stranded DNA breaks. For imaging, we used GSMs as a contrast agent for both computed tomography (CT) and magnetic resonance imaging (MRI) studies of stereotactically implanted GBM tumors in a mouse model, and found that MRI but not CT was sufficiently sensitive to detect and delineate tumor borders after administration and accumulation of GSMs. These results suggest that with further development and testing, GSMs may potentially be integrated into both imaging and treatment of brain tumors, serving a theranostic purpose as both an MRI-based contrast agent and a radiosensitizer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1166/jbn.2016.2173

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 119

Metadata

Authors
Sun, L., Joh, D. Y., Al-Zaki, A., Stangl, M., Murty, S., Davis, J. J., Baumann, B. C., Alonso-Basanta, M., Kao, G. D., Tsourkas, A., & Dorsey, J. F.
Venue
Journal of Biomedical Nanotechnology
Published
2016-02-01
Volume
12
Issue
2
Pages
347-356
ISSN
1550-7033 (ISSN-L)
OpenAlex
W2424728169
Cited by
119
References
1
FWCI
5.62
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.