Delivery of High Mobility Group Box-1 siRNA Using Brain-Targeting Exosomes for Ischemic Stroke Therapy
The DOI matches its Crossref record.
Abstract
Ischemic strokes are caused by decreased blood flow into the brain, due to narrowed cerebral arteries. In the ischemic brain, high-mobility group box 1 (HMGB1) is released into extracellular spaces and induces inflammatory reactions. In this study, HMGB1 small interfering RNA (siRNA) was delivered into ischemic brains by intravenous administration using rabies virus glycoprotein (RVG) peptide-decorated exosomes. A fusion protein of RVG and Lamp2b was expressed in 293T cells. Since Lamp2b is an exosome membrane-integral protein, RVG-Lamp2b is integrated into the exosomes, producing RVG-decorated exosomes (RVG-Exo). HMGB1-siRNA was loaded into RVG-Exo and unmodified exosomes (Unmod-Exo) by electroporation. The exosomes were homogenous with a size of less than 50 nm and a negative surface charge. In vitro delivery assays showed that RVG-Exo showed higher efficiency to Neuro2A cells than Unmod-Exo. Also, HMGB1 levels were reduced more effectively by RVG-Exo/HMGB1-siRNA. In vivo delivery efficiency and therapeutic effects of RVG-Exo/HMGB1-siRNA were evaluated in a middle cerebral artery occlusion (MCAO) model. RVG-Exo/HMGB1-siRNA, Unmod-Exo/HMGB1-siRNA, and PEI25k/HMGB1-siRNA were administrated into the MCAO model intravenously through the tail vein. The results showed that HMGB1, tumor necrosis factor-α (TNF-α), and apoptosis levels in the brain were reduced in the RVG-Exo/HMGB1-siRNA group more efficiently than the other groups. In addition, the infarct size was decreased in the RVG-Exo/HMGB1 group more effectively than the other groups. These results suggest that RVG-Exo with HMGB1-siRNA may have potential as a therapeutic system for the treatment of ischemic strokes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Therapeutic siRNA: state of the art
Hu, B., Zhong, L., Weng, Y., Peng, L., Huang, Y., Zhao, Y., & Liang, X.-J. (2020) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-020-0207-x · Cited by 1,586
Exosome engineering: Current progress in cargo loading and targeted delivery
Fu, S., Wang, Y., Xia, X., & Zheng, J. C. (2020) · NanoImpact · doi:10.1016/j.impact.2020.100261 · Cited by 444
Xu, M., Feng, T., Liu, B., Qiu, F., Xu, Y., Zhao, Y., & Zheng, Y. (2021) · Theranostics · doi:10.7150/thno.62330 · Cited by 229
Overview and Update on Methods for Cargo Loading into Extracellular Vesicles
Han, Y., Jones, T. W., Dutta, S., Zhu, Y., Wang, X., Narayanan, S. P., Fagan, S. C., & Zhang, D. (2021) · Processes · doi:10.3390/pr9020356 · Cited by 204
Liu, Q., Li, D., Pan, X., & Liang, Y. (2023) · Journal of Nanobiotechnology · doi:10.1186/s12951-023-02081-0 · Cited by 201
“H M G B 1 - s i R N A H i g h b r a i n a cc u m u l a t i o n , e ff e c t i v e g e n e s i l e n c i n g i n i s c h e m i c s t r o k e s [ 92 ] O p i o i d r e c e p t o r m u s i R N A D e l i v e r y o f s i R N A t o t h e c e n t r a l n e r v o u s s y s t e m a n d r e s t r a i n i n g…”
Background
Metadata
- Authors
- Kim, M., Kim, G., Hwang, D. W., & Lee, M.
- Venue
- Journal of Biomedical Nanotechnology
- Publisher
- American Scientific Publishers
- Published
- 2019-12-01
- Volume
- 15
- Issue
- 12
- Pages
- 2401-2412
- ISSN
- 1550-7033 (ISSN-L)
- OpenAlex
- W2990574370
- Cited by
- 90
- References
- 0
- FWCI
- 3.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Delivery of High Mobility Group Box-1 siRNA Using Brain-Targeting Exosomes for Ischemic Stroke Therapy. https://app.cochat.ai/papers/10.1166/jbn.2019.2866
- The paper
- Kim, M., Kim, G., Hwang, D. W., & Lee, M. (2019). Delivery of High Mobility Group Box-1 siRNA Using Brain-Targeting Exosomes for Ischemic Stroke Therapy. Journal of Biomedical Nanotechnology. https://doi.org/10.1166/jbn.2019.2866
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.