Tumour Cell Toxicity of Intracellular Hyperthermia Mediated by Magnetic Nanoparticles
The DOI matches its Crossref record.
Abstract
Intracellular hyperthermia is a process by which malignant cells can be selectively killed by heat generated by nanomediators located inside the cell. Here we show that maghemite anionic nanoparticles are efficiently captured by human prostatic tumor cells (PC3) and concentrate within intracellular vesicles. When submitted to an alternative magnetic field, maghemite nanocrystals generate heat from the cell inside, inducing a temperature elevation of eight degree in a loose pellet of 20 million magnetically labeled cells. We demonstrate that this heating modality was as lethal as external waterbath heating. A one hour AC magnetic field (700 kHz-31 mT) exposure of the magnetically labeled cells killed 44% of the cells. Interestingly, more than 80% of the cells were killed after being submitted twice to the magnetic field. Finally, when magnetic cells coexist with non magnetic ones, the same proportions of cells were damaged for both populations, after magnetic field exposure. These findings pave the way for an efficient cell killing mediated by intracellular magnetic hyperthermia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guardia, P., Di Corato, R., Lartigue, L., Wilhelm, C., Espinosa, A., Garcia-Hernandez, M., Gazeau, F., Manna, L., & Pellegrino, T. (2012) · ACS Nano · doi:10.1021/nn2048137 · Cited by 752
Self-citationFiguerola, A., Di Corato, R., Manna, L., & Pellegrino, T. (2010) · Pharmacological Research · doi:10.1016/j.phrs.2009.12.012 · Cited by 480
Multi-functional magnetic nanoparticles for magnetic resonance imaging and cancer therapy
Yallapu, M. M., Othman, S. F., Curtis, E. T., Gupta, B. K., Jaggi, M., & Chauhan, S. C. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.11.028 · Cited by 479
Potential Toxicity of Iron Oxide Magnetic Nanoparticles: A Review
Malhotra, N., Lee, J.-S., Liman, R. A. D., Ruallo, J. M. S., Villaflores, O. B., Ger, T.-R., & Hsiao, C.-D. (2020) · Molecules · doi:10.3390/molecules25143159 · Cited by 470
Lartigue, L., Hugounenq, P., Alloyeau, D., Clarke, S. P., Lévy, M., Bacri, J.-C., Bazzi, R., Brougham, D. F., Wilhelm, C., & Gazeau, F. (2012) · ACS Nano · doi:10.1021/nn304477s · Cited by 421
Self-citationUniversal cell labelling with anionic magnetic nanoparticles
Wilhelm, C., & Gazeau, F. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.016 · Cited by 343
Self-citationVillanueva, A., Cañete, M., Roca, A. G., Calero, M., Veintemillas-Verdaguer, S., Serna, C. J., del Puerto Morales, M., & Miranda, R. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/11/115103 · Cited by 299
Optimizing Magnetic Nanoparticle Design for Nanothermotherapy
Gazeau, F., Lévy, M., & Wilhelm, C. (2008) · Nanomedicine · doi:10.2217/17435889.3.6.831 · Cited by 258
Self-citationApplications of nanomaterials inside cells
Gao, J., & Xu, B. (2009) · Nano Today · doi:10.1016/j.nantod.2008.10.009 · Cited by 249
Metadata
- Authors
- Wilhelm, C., Fortin, J.-P., & Gazeau, F.
- Venue
- Journal of Nanoscience and Nanotechnology
- Publisher
- American Scientific Publishers
- Published
- 2007-08-01
- Volume
- 7
- Issue
- 8
- Pages
- 2933-2937
- ISSN
- 1533-4880 (ISSN-L)
- 0000-0000
- OpenAlex
- W2012295253
- Cited by
- 69
- References
- 0
- FWCI
- 4.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.