The DOI matches its Crossref record.
Relationships between Age, Blood Pressure, and Retinal Vessel Diameters in an Older Population
Abstract
PURPOSE: To describe the cross-sectional relationships between age, blood pressure (BP), and quantitative measures of retinal vessel diameters in an older Australian population. METHODS: Retinal photographs from right eyes of participants (n = 3654, aged 49+ years) in the Blue Mountains Eye study taken during baseline examinations (1992-1994) were digitized. The width of all retinal vessels located 0.5 to 1.0 disc diameters from the disc margin was measured by a computer-assisted method. Summarized estimates for central retinal arteriolar equivalent (CRAE) and central retinal venular equivalent (CRVE) represent average retinal vessel diameters. The arteriole-to-venule ratio (AVR) was calculated. Associations between age and BP and CRAE, CRVE, and AVR were assessed with generalized linear models. RESULTS: Retinal vessel diameters decreased with increasing age in both men and women. CRAE and CRVE decreased by 4.8 microm and 4.1 microm, respectively, per decade increase in age, after adjusting for sex and mean arterial blood pressure. Mean AVR declined by 0.01 for each increasing decade of age, until 79 years. After adjustment for age, sex, smoking, and body mass index, CRAE, CRVE and AVR were all significantly and inversely associated with BP. For every 10-mm Hg increase in mean arterial blood pressure, AVR decreased by 0.012 and CRAE and CRVE decreased by 3.5 microm and 0.96 microm, respectively. CONCLUSIONS: Retinal arteriolar and venular diameters narrow with increasing age, and these parameters are inversely related to BP, independent of age, gender, and smoking. The findings are consistent with those from the Atherosclerosis Risk in Communities Study suggesting that decreased retinal vessel diameters may reflect microvascular damage from elevated blood pressure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wong, T., & Mitchell, P. (2007) · The Lancet · doi:10.1016/s0140-6736(07)60198-6 · Cited by 585
Self-citationOwen, C. G., Rudnicka, A. R., Mullen, R., Barman, S. A., Monekosso, D., Whincup, P. H., Ng, J., & Paterson, C. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3018 · Cited by 465
McGeechan, K., Liew, G., Macaskill, P., Irwig, L., Klein, R., Klein, B. E. K., Wang, J. J., Mitchell, P., Vingerling, J. R., de Jong, P. T. V. M., et al. (2009) · American Journal of Epidemiology · doi:10.1093/aje/kwp306 · Cited by 347
Self-citationAn approach to localize the retinal blood vessels using bit planes and centerline detection
Fraz, M. M., Barman, S. A., Remagnino, P., Hoppe, A., Basit, A., Uyyanonvara, B., Rudnicka, A. R., & Owen, C. G. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2011.08.009 · Cited by 340
Retinal Vessel Diameters and Risk of Hypertension: The Rotterdam Study
Ikram, M. K., Witteman, J. C. M., Vingerling, J. R., Breteler, M. M. B., Hofman, A., & de Jong, P. T. V. M. (2006) · Hypertension · doi:10.1161/01.hyp.0000199104.61945.33 · Cited by 339
Metadata
- Authors
- Leung, H., Wang, J. J., Rochtchina, E., Tan, A. G., Wong, T. Y., Klein, R., Hubbard, L. D., & Mitchell, P.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2003-07-01
- Volume
- 44
- Issue
- 7
- Pages
- 2900
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2039519120
- Cited by
- 281
- References
- 0
- FWCI
- 10.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationships between Age, Blood Pressure, and Retinal Vessel Diameters in an Older Population. https://app.cochat.ai/papers/10.1167/iovs.02-1114
- The paper
- Leung, H., Wang, J. J., Rochtchina, E., Tan, A. G., Wong, T. Y., Klein, R., Hubbard, L. D., & Mitchell, P. (2003). Relationships between Age, Blood Pressure, and Retinal Vessel Diameters in an Older Population. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.02-1114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.