CoChat

Migration of Retinal Cells through a Perforated Membrane: Implications for a High-Resolution Prosthesis

Open access
Palanker, Daniel, Huie, Philip, Vankov, Alexander, Aramant, Robert, Seiler, Magdalene, Fishman, Harvey, Marmor, Michael, Blumenkranz, Mark · 2004 · Investigative Opthalmology & Visual Science
Cited by 69

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

PURPOSE: One of the critical difficulties in design of a high-resolution retinal implant is the proximity of stimulating electrodes to the target cells. This is a report of a phenomenon of retinal cellular migration into a perforated membrane that may help to address this problem. METHODS: Mylar membranes with an array of perforations (3-40 microm in diameter) were used as a substrate for in vitro retinal culture (chicken, rats) and were also transplanted into the subretinal space of adult RCS rats. A membrane was also constructed with a seal on one side to restrict the migration. RESULTS: Retinal tissue in vitro grew within 3 days through perforations of greater than 5 microm in diameter when the membranes were positioned on the photoreceptor side, but no migration occurred if the implant was placed on the inner retinal surface. Histology with light microscopy and transmission electron microscopy (TEM) demonstrated that migrating cells retain neuronal structures for signal transduction. Similar growth of RCS rat retinal cells occurred in vivo within 5 days of implantation. A basal seal kept the migrating tissue within a small membrane compartment. CONCLUSIONS: Retinal neurons migrate within a few days into perforations (> 5 microm in diameter) of a membrane placed into the subretinal space. This may provide a means of gaining close proximity between electrodes in a retinal prosthetic chip and target cells, and thus allow a greater density of stimulating elements to subserve higher resolution. Further studies are needed to explore the long-term stability of the retinal migration.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.03-1327

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 69

Metadata

Authors
Palanker, D., Huie, P., Vankov, A., Aramant, R., Seiler, M., Fishman, H., Marmor, M., & Blumenkranz, M.
Venue
Investigative Opthalmology & Visual Science
Published
2004-09-01
Volume
45
Issue
9
Pages
3266
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2086205688
Cited by
69
References
2
FWCI
1.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.