Visual perception in a blind subject with a chronic microelectronic retinal prosthesis
Open accessAbstract
A retinal prosthesis was permanently implanted in the eye of a completely blind test subject. This report details the results from the first 10 weeks of testing with the implant subject. The implanted device included an extraocular case to hold electronics, an intraocular electrode array (platinum disks, 4 x 4 arrangement) designed to interface with the retina, and a cable to connect the electronics case to the electrode array. The subject was able to see perceptions of light (spots) on all 16 electrodes of the array. In addition, the subject was able to use a camera to detect the presence or absence of ambient light, to detect motion, and to recognize simple shapes.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Due to axonal activation, phosphenes often appear with an elongated shape distorting the image perceived by the patient.
“Due to axonal activation, phosphenes often appear with an elongated shape distorting the image perceived by the patient [46].”
From Advances in visual prostheses: engineering and biological challenges (2022) · cites this paper as [46]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Prevalence of age-related maculopathy
Klein, R., Klein, B. E. K., & Linton, K. L. P. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31871-8 · Cited by 1,845 · see citing works
The Five-year Incidence and Progression of Age-related Maculopathy
Klein, R., Klein, R., Jensen, S. C., & Meuer, S. M. (1997) · Ophthalmology · doi:10.1016/s0161-6420(97)30368-6 · Cited by 1,148 · see citing works
Will Retinal Implants Restore Vision?
Zrenner, E. (2002) · Science · doi:10.1126/science.1067996 · Cited by 726 · see citing works
Preservation of the Inner Retina in Retinitis Pigmentosa
Santos, A. (1997) · Archives of Ophthalmology · doi:10.1001/archopht.1997.01100150513011 · Cited by 644 · see citing works
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602 · see citing works
Self-citationPattern electrical stimulation of the human retina
Humayun, M. S., de Juan, E., Weiland, J. D., Dagnelie, G., Katona, S., Greenberg, R. J., & Suzuki, S. (1999) · Vision Research · doi:10.1016/s0042-6989(99)00052-8 · Cited by 593 · see citing works
Self-citationMorphometric analysis of the extramacular retina from postmortem eyes with retinitis pigmentosa.
Humayun, M. S., Prince, M. R., de Juan, E., Barrón, Y., Moskowitz, M., Klock, I. B., & Milam, A. H. (1999) · PubMed · Cited by 366 · see citing works
Self-citationNeural prostheses : fundamental studies
Agnew, W. F., & McCreery, D. B. (1990) · Medical Entomology and Zoology · Cited by 316 · see citing works
Learning Retina Implants with Epiretinal Contacts
Eckmiller, R. (2009) · Ophthalmic Research · doi:10.1159/000268026 · Cited by 257 · see citing works
Subretinal electrical stimulation of the rabbit retina
Chow, A. Y., & Chow, V. Y. (1997) · Neuroscience Letters · doi:10.1016/s0304-3940(97)00185-7 · Cited by 242 · see citing works
Heckenlively, J. R. (1987) · Cited by 229 · see citing works
The Development of Subretinal Microphotodiodes for Replacement of Degenerated Photoreceptors
Zrenner, E., Miliczek, K.-D., Gabel, V. P., Graf, H., Guenther, E., Haemmerle, H., Hoefflinger, B., Köhler, K., Nisch, W., Schubert, M. B., et al. (2009) · Ophthalmic Research · doi:10.1159/000268025 · Cited by 214 · see citing works
A computational model of electrical stimulation of the retinal ganglion cell
Greenberg, R. J., Velte, T. J., Humayun, M. S., Scarlatis, G. N., & de Juan, E. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.759051 · Cited by 185 · see citing works
Self-citationMORPHOMETRIC ANALYSIS OF THE MACULA IN EYES WITH DISCIFORM AGE-RELATED MACULAR DEGENERATION
KIM, S. Y., SADDA, S., PEARLMAN, J., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00012 · Cited by 158 · see citing works
Self-citationPerformance over time of adult patients using the Ineraid or Nucleus cochlear implant
Tyler, R. S., Parkinson, A. J., Woodworth, G. G., Lowder, M. W., & Gantz, B. J. (1997) · The Journal of the Acoustical Society of America · doi:10.1121/1.419724 · Cited by 154 · see citing works
KIM, S. Y., SADDA, S., HUMAYUN, M. S., de JUAN, E., MELIA, B. M., & GREEN, W. R. (2002) · Retina · doi:10.1097/00006982-200208000-00011 · Cited by 117 · see citing works
Self-citationREVIEW ■ : Prospects for a Visual Prosthesis
Rizzo, J. F., & Wyatt, J. L. (1997) · The Neuroscientist · doi:10.1177/107385849700300413 · Cited by 114 · see citing works
Intraocular Retinal Prosthesis
Jaeger, D., & Jung, R. (2015) · Springer eBooks · doi:10.1007/978-1-4614-6675-8_100279 · Cited by 104 · see citing works
Intraocular retinal prosthesis
Weiland, J. D., & Humayun, M. S. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705748 · Cited by 71 · see citing works
Self-citationHumayun, M. S., & de Juan, E. (1998) · Eye · doi:10.1038/eye.1998.151 · Cited by 50 · see citing works
Self-citation
Flagged first, then by citations
1 of the 21 references couldn’t be matched to a known paper.
Research works printed but not linked: 1
- Webb, R. L., Pyman, B. C., Franz, B. K. H. G., & Clark, G. M. (1990). The surgery of cochlear implantation. In G. M. Clark, Y. C. Tong, & J. F. Patrick (Eds.), Cochlear prostheses (pp. 153-180). Churchill Livingstone: Edinburgh.
Cited by
Sorted by citations
Interim results from the international trial of Second Sight's visual prosthesis
Humayun, M. S., Dorn, J. D., da Cruz, L., Dagnelie, G., Sahel, J.-A., Stanga, P. E., Cideciyan, A. V., Duncan, J. L., Eliott, D., Filley, E., et al. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.09.028 · Cited by 700 · see citing works
Self-citationJow, U.-M., & Ghovanloo, M. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.913130 · Cited by 628 · see citing works
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580 · see citing works
Rizzo, J. F., Wyatt, J., Loewenstein, J., Kelly, S., & Shire, D. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-0817 · Cited by 478 · see citing works
Dias, M. F., Joo, K., Kemp, J. A., Fialho, S. L., Silva‐Cunha, A., Woo, S. J., & Kwon, Y. J. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.10.004 · Cited by 420 · see citing works
Weiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371 · see citing works
Self-citationda Cruz, L., Coley, B. F., Dorn, J., Merlini, F., Filley, E., Christopher, P., Chen, F. K., Wuyyuru, V., Sahel, J., Stanga, P., et al. (2013) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2012-301525 · Cited by 359 · see citing works
Self-citationThe Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351 · see citing works
Electrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dąbrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 336 · see citing works
Design of a high-resolution optoelectronic retinal prosthesis
Palanker, D., Vankov, A., Huie, P., & Baccus, S. A. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/012 · Cited by 330 · see citing works
Rodger, D. C., FONG, A., LI, W., Ameri, H., AHUJA, A., GUTIERREZ, C., Lavrov, I. A., ZHONG, H., MENON, P., & Meng, E. F. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.10.069 · Cited by 327 · see citing works
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272 · see citing works
Self-citationAn Integrated 256-Channel Epiretinal Prosthesis
Chen, K., Yang, Z., Hoang, L., Weiland, J. D., Humayun, M. S., & Liu, W. (2010) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2010.2055371 · Cited by 266 · see citing works
Self-citationOrganic electrode coatings for next-generation neural interfaces
Robles, U. A. A., Woolley, A. J., Poole-Warren, L. A., Lovell, N. H., & Green, R. A. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00015 · Cited by 255 · see citing works
Abidian, M. R., Ludwig, K. A., Marzullo, T., Martin, D. C., & Kipke, D. R. (2009) · Advanced Materials · doi:10.1002/adma.200900887 · Cited by 256 · see citing works
Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments
Jow, U.-M., & Ghovanloo, M. (2009) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2009.2025366 · Cited by 241 · see citing works
Photochemical Restoration of Visual Responses in Blind Mice
Polosukhina, A., Litt, J., Tochitsky, I., Nemargut, J. P., Sychev, Y., Kouchkovsky, I. D., Huang, T., Borges, K., Trauner, D. H., Gelder, R. N. V., et al. (2012) · Neuron · doi:10.1016/j.neuron.2012.05.022 · Cited by 238 · see citing works
Visual Performance Using a Retinal Prosthesis in Three Subjects With Retinitis Pigmentosa
Yanai, D., Weiland, J. D., Mahadevappa, M., Greenberg, R. J., Fine, I., & Humayun, M. S. (2007) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2007.01.027 · Cited by 233 · see citing works
Self-citationClinical Characteristics and Current Therapies for Inherited Retinal DegenerationsPreprint
Sahel, J., Marazova, K., & Audo, I. S. (2014) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a017111 · Cited by 234 · see citing works
Designing artificial cells to harness the biological ion concentration gradient
Xu, J., & LaVan, D. A. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.274 · Cited by 229 · see citing works
Artificial vision: needs, functioning, and testing of a retinal electronic prosthesis
Chader, G. J., Weiland, J. D., & Humayun, M. S. (2009) · Progress in brain research · doi:10.1016/s0079-6123(09)17522-2 · Cited by 226 · see citing works
Self-citationAn update on retinal prostheses
Ayton, L. N., Barnes, N., Dagnelie, G., Fujikado, T., Goetz, G., Hornig, R., Jones, B. W., Muqit, M. M. K., Rathbun, D. L., Stingl, K., et al. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.11.029 · Cited by 223 · see citing works
Self-citationFujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Morimoto, T., Ikuno, Y., Nishida, K., Kishima, H., Maruo, T., Konoma, K., et al. (2011) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.10-6836 · Cited by 216 · see citing works
Noorsal, E., Sooksood, K., Xu, H., Hornig, R., Becker, J., & Ortmanns, M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2164667 · Cited by 212 · see citing works
A Method for Generating Precise Temporal Patterns of Retinal Spiking Using Prosthetic Stimulation
Fried, S. I., Hsueh, H.-A., & Werblin, F. S. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00849.2005 · Cited by 212 · see citing works
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206 · see citing works
Factors affecting perceptual thresholds in epiretinal prostheses
de Balthasar, C., Patel, S., Roy, A., Freda, R., Greenwald, S., Horsager, A., Mahadevappa, M., Yanai, D., McMahon, M. J., Humayun, M. S., et al. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-0696 · Cited by 204 · see citing works
Self-citationAxonal Sodium-Channel Bands Shape the Response to Electric Stimulation in Retinal Ganglion Cells
Fried, S. I., Lasker, A., Desai, N. J., Eddington, D. K., & Rizzo, J. F. (2009) · Journal of Neurophysiology · doi:10.1152/jn.91081.2008 · Cited by 206 · see citing works
Demonstration of artificial visual percepts generated through thalamic microstimulation
Pezaris, J. S., & Reid, R. C. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0608563104 · Cited by 195 · see citing works
The functional performance of the Argus II retinal prosthesis
Stronks, H. C., & Dagnelie, G. (2014) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.862494 · Cited by 189 · see citing works
Self-citationSputtered iridium oxide films for neural stimulation electrodes
Cogan, S. F., Ehrlich, J., Plante, T. D., Smirnov, A., Shire, D. B., Gingerich, M. D., & Rizzo, J. F. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31223 · Cited by 188 · see citing works
Perceptual thresholds and electrode impedance in three retinal prosthesis subjects
Mahadevappa, M., Weiland, J. D., Yanai, D., Fine, I., Greenberg, R. J., & Humayun, M. S. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.848687 · Cited by 187 · see citing works
Self-citationWeiland, J. D., & Humayun, M. S. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2314733 · Cited by 186 · see citing works
Self-citationWhat blindness can tell us about seeing again: merging neuroplasticity and neuroprostheses
Merabet, L. B., Rizzo, J. F., Amedi, A., Somers, D. C., & Pascual-Leone, A. (2005) · Nature reviews. Neuroscience · doi:10.1038/nrn1586 · Cited by 179 · see citing works
Review and update: Current treatment trends for patients with retinitis pigmentosa
Shintani, K., Shechtman, D. L., & Gurwood, A. S. (2009) · Optometry · doi:10.1016/j.optm.2008.01.026 · Cited by 177 · see citing works
Simulating prosthetic vision: I. Visual models of phosphenes
Chen, S. C., Suaning, G. J., Morley, J. W., & Lovell, N. H. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.003 · Cited by 172 · see citing works
Román, A. J., Schwartz, S., Alemán, T. S., Cideciyan, A. V., Chico, J. D., Windsor, E. A. M., Gardner, L. M., Ying, G., Smilko, E. E., Maguire, M. G., et al. (2004) · Experimental Eye Research · doi:10.1016/j.exer.2004.09.008 · Cited by 165 · see citing works
Nanduri, D., Fine, I., Horsager, A., Boynton, G. M., Humayun, M. S., Greenberg, R. J., & Weiland, J. D. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8401 · Cited by 163 · see citing works
Self-citationVisually Guided Performance of Simple Tasks Using Simulated Prosthetic Vision
Hayes, J. S., Yin, V. T., Piyathaisere, D. V., Weiland, J. D., Humayun, M. S., & Dagnelie, G. (2003) · Artificial Organs · doi:10.1046/j.1525-1594.2003.07309.x · Cited by 162 · see citing works
Self-citationJensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159 · see citing works
Wilke, R., Gabel, V.-P., Sachs, H., Bartz Schmidt, K.-U., Gekeler, F., Besch, D., Szurman, P., Stett, A., Wilhelm, B., Peters, T., et al. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6946 · Cited by 155 · see citing works
Sivaprakasam, M., Liu, W., Humayun, M. S., & Weiland, J. D. (2005) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2005.843630 · Cited by 155 · see citing works
Self-citationSelective Activation of Neuronal Targets With Sinusoidal Electric Stimulation
Freeman, D. K., Eddington, D. K., Rizzo, J. F., & Fried, S. I. (2010) · Journal of Neurophysiology · doi:10.1152/jn.00551.2010 · Cited by 149 · see citing works
Feasibility Study of a Retinal Prosthesis
Caspi, A. (2009) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2009.20 · Cited by 149 · see citing works
Fujikado, T., Morimoto, T., Kanda, H., Kusaka, S., Nakauchi, K., Ozawa, M., Matsushita, K., Sakaguchi, H., Ikuno, Y., Kamei, M., et al. (2007) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-007-0563-z · Cited by 147 · see citing works
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138 · see citing works
Graphene Transistors for Bioelectronics
Hess, L. H., Seifert, M., & Garrido, J. A. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2261031 · Cited by 135 · see citing works
Electronic retinal implants and artificial vision: journey and present
Mills, J. O., Jalil, A., & Stanga, P. E. (2017) · Eye · doi:10.1038/eye.2017.65 · Cited by 133 · see citing works
Gold nanostructures: synthesis, properties, and neurological applications
Zare, I., Yaraki, M. T., Speranza, G., Najafabadi, A. H., Shourangiz-Haghighi, A., Nik, A. B., Manshian, B. B., Saraiva, C., Soenen, S. J., Kogan, M. J., et al. (2022) · Chemical Society Reviews · doi:10.1039/d1cs01111a · Cited by 132 · see citing works
Optoelectronic retinal prosthesis: system design and performance
Loudin, J., Simanovskii, D. M., Vijayraghavan, K., Sramek, C., Butterwick, A., Huie, P., McLean, G. Y., & Palanker, D. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/1/s09 · Cited by 130 · see citing works
Gauvain, G., Akolkar, H., Chaffiol, A., Arcizet, F., Khoei, M. A., Desrosiers, M., Jaillard, C., Caplette, R., Marre, O., Bertin, S., et al. (2021) · Communications Biology · doi:10.1038/s42003-020-01594-w · Cited by 131 · see citing works
Hambright, D., Park, K., Brooks, M., McKay, R. D. G., Swaroop, A., & Nasonkin, I. O. (2012) · Europe PMC (PubMed Central) · Cited by 125 · see citing works
Neuroprotective Effect of Subretinal Implants in the RCS Rat
Pardue, M. T., Phillips, M. J., Yin, H., Sippy, B. D., Webb-Wood, S., Chow, A. Y., & Ball, S. L. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0515 · Cited by 119 · see citing works
Optimization of Data Coils in a Multiband Wireless Link for Neuroprosthetic Implantable Devices
Jow, U.-M., & Ghovanloo, M. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2049491 · Cited by 118 · see citing works
Besch, D., Sachs, H., Szurman, P., Gülicher, D., Wilke, R. G. H., Reinert, S., Zrenner, E., Bartz‐Schmidt, K. U., & Gekeler, F. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.131961 · Cited by 115 · see citing works
Development of visual Neuroprostheses: trends and challenges.
Fernandez, E. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0013-8 · Cited by 114 · see citing works
The primate model for understanding and restoring vision
Picaud, S. A., Dalkara, D., Marazova, K., Goureau, O., Roska, B., & Sahel, J. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1902292116 · Cited by 114 · see citing works
AnIn VitroModel of a Retinal Prosthesis
Ahuja, A. K., Behrend, M. R., Kuroda, M., Humayun, M. S., & Weiland, J. D. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.919126 · Cited by 111 · see citing works
Self-citationResponses of rabbit retinal ganglion cells to electrical stimulation with an epiretinal electrode
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/003 · Cited by 110 · see citing works
Retinitis Pigmentosa and Allied Disorders
Gregory-Evans, K., Pennesi, M. E., & Weleber, R. G. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4557-0737-9.00040-0 · Cited by 112 · see citing works
Focal activation of the feline retina via a suprachoroidal electrode array
Wong, Y. T., Chen, S. C., Seo, J. M., Morley, J. W., Lovell, N. H., & Suaning, G. J. (2009) · Vision Research · doi:10.1016/j.visres.2009.02.018 · Cited by 109 · see citing works
Retinal prostheses: current challenges and future outlook
Winter, J. O., Cogan, S. F., & Rizzo, J. F. (2007) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856207781494403 · Cited by 109 · see citing works
Effect of shape and coating of a subretinal prosthesis on its integration with the retina
Butterwick, A., Huie, P., Jones, B. W., Marc, R. E., Marmor, M. F., & Palanker, D. (2008) · Experimental Eye Research · doi:10.1016/j.exer.2008.09.018 · Cited by 107 · see citing works
Composite biomolecule/PEDOT materials for neural electrodes
Asplund, M., von Holst, H., & Inganäs, O. (2008) · Biointerphases · doi:10.1116/1.2998407 · Cited by 109 · see citing works
A 32-Site 4-Channel High-Density Electrode Array for a Cochlear Prosthesis
Bhatti, P. T., & Wise, K. D. (2006) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2006.884862 · Cited by 109 · see citing works
Tsai, D., Morley, J. W., Suaning, G. J., & Lovell, N. H. (2009) · Journal of Neurophysiology · doi:10.1152/jn.00545.2009 · Cited by 108 · see citing works
Predicting visual sensitivity in retinal prosthesis patients
Horsager, A., Greenwald, S. H., Weiland, J. D., Humayun, M. S., Greenberg, R. J., McMahon, M. J., Boynton, G. M., & Fine, I. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2595 · Cited by 107 · see citing works
Self-citationDevelopment of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity
Fernández, E., Pelayo, F., Romero, S., Bongard, M., Marin, C., Alfaro, A., & Merabet, L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/r01 · Cited by 105 · see citing works
Monolithic Encapsulation of Implantable Neuroprosthetic Devices Using Liquid Crystal Polymers
Lee, S. W., Min, K. S., Jeong, J., Kim, J., & Kim, S. J. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2136341 · Cited by 104 · see citing works
Loewenstein, J. I. (2004) · Archives of Ophthalmology · doi:10.1001/archopht.122.4.587 · Cited by 101 · see citing works
Fujikado, T., Kamei, M., Sakaguchi, H., Kanda, H., Endo, T., Hirota, M., Morimoto, T., Nishida, K., Kishima, H., Terasawa, Y., et al. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-20367 · Cited by 101 · see citing works
Retinitis pigmentosa: understanding the clinical presentation, mechanisms and treatment options
Kalloniatis, M., & Fletcher, E. L. (2004) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2004.tb03152.x · Cited by 100 · see citing works
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98 · see citing works
Nanotechnology and Nanomaterials for Improving Neural Interfaces
Wang, M., Mi, G., Shi, D., Bassous, N. J., Hickey, D. J., & Webster, T. J. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201700905 · Cited by 97 · see citing works
Getting signals into the brain: visual prosthetics through thalamic microstimulation
Pezaris, J. S., & Eskandar, E. N. (2009) · Neurosurgical FOCUS · doi:10.3171/2009.4.focus0986 · Cited by 98 · see citing works
Scalable high lead-count parylene package for retinal prostheses
Rodger, D. C., Weiland, J. D., Humayun, M. S., & Tai, Y.-C. (2006) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.11.010 · Cited by 96 · see citing works
Self-citationCellular regeneration strategies for macular degeneration: past, present and future
Chichagova, V., Hallam, D., Collin, J., Zerti, D., Dorgau, B., Felemban, M., Lako, M., & STEEL, D. H. (2018) · Eye · doi:10.1038/s41433-018-0061-z · Cited by 96 · see citing works
Spatiotemporal Interactions in Retinal Prosthesis Subjects
Horsager, A., Greenberg, R. J., & Fine, I. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3746 · Cited by 95 · see citing works
Self-citationBrightness as a Function of Current Amplitude in Human Retinal Electrical Stimulation
Greenwald, S. H., Horsager, A., Humayun, M. S., Greenberg, R. J., McMahon, M. J., & Fine, I. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2897 · Cited by 95 · see citing works
Self-citationVisual resolution with retinal implants estimated from recordings in cat visual cortex
Eckhorn, R., Wilms, M., Schanze, T., Eger, M., Hesse, L., Eysel, U. T., Kisvárday, Z. F., Zrenner, E., Gekeler, F., Schwahn, H., et al. (2006) · Vision Research · doi:10.1016/j.visres.2006.01.034 · Cited by 94 · see citing works
Paraskevopoulou, S. E., Barsakcioglu, D. Y., Saberi, M. R., Eftekhar, A., & Constandinou, T. G. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.01.012 · Cited by 92 · see citing works
Cortical Activation Via an Implanted Wireless Retinal Prosthesis
Walter, P., ́rday, Z. ́. F. K., Görtz, M., Alteheld, N., Rößler, G., Stieglitz, T., & Eysel, U. T. (2005) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.04-0924 · Cited by 92 · see citing works
Dagnelie, G., Barnett, D., Humayun, M. S., & Thompson, R. W. (2006) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.05-0157 · Cited by 90 · see citing works
Self-citationArtificial vision through neuronal stimulation
Fernandes, R. A. B., Diniz, B., Ribeiro, R., & Humayun, M. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.01.063 · Cited by 90 · see citing works
Self-citationA Complete 256-Electrode Retinal Prosthesis Chip
Tran, N., Bai, S., Yang, J., Chun, H., Kavehei, O., Yang, Y., Muktamath, V., Ng, D., Meffin, H., Halpern, M., et al. (2014) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2014.2298037 · Cited by 90 · see citing works
Implantable CMOS Biomedical Devices
Ohta, J., Tokuda, T., Sasagawa, K., & Noda, T. (2009) · Sensors · doi:10.3390/s91109073 · Cited by 89 · see citing works
Joucla, S., & Yvert, B. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.10.003 · Cited by 88 · see citing works
Im, M., & Fried, S. I. (2015) · The Journal of Physiology · doi:10.1113/jp270606 · Cited by 86 · see citing works
Tunable retina encoders for retina implants: why and how
Eckmiller, R., Neumann, D., & Baruth, O. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/1/011 · Cited by 86 · see citing works
Laminar Variation in Threshold for Detection of Electrical Excitation of Striate Cortex by Macaques
DeYoe, E. A., Lewine, J. D., & Doty, R. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00407.2005 · Cited by 85 · see citing works
Schiller, P. H., & Tehovnik, E. J. (2008) · Perception · doi:10.1068/p6100 · Cited by 85 · see citing works
Raspopović, S., Petrini, F. M., Żelechowski, M., & Valle, G. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2600560 · Cited by 84 · see citing works
Development of Microelectrode Arrays for Artificial Retinal Implants Using Liquid Crystal Polymers
Lee, S.-W., Seo, J.-M., Ha, S., Kim, E., Chung, H., & Kim, S. J. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.09-3743 · Cited by 83 · see citing works
Psychophysical evaluation for visual prosthesis
Dagnelie, G. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160529 · Cited by 82 · see citing works
Self-citationThe Argus™ II retinal prosthesis: Factors affecting patient selection for implantation
Ahuja, A., & Behrend, M. R. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.01.002 · Cited by 82 · see citing works
Inner Retinal Mechanisms Engaged by Retinal Electrical Stimulation
Margalit, E., & Thoreson, W. B. (2006) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.05-1093 · Cited by 81 · see citing works
Using magnetic resonance imaging to assess visual deficits: a review
Brown, H. D. H., Woodall, R., Kitching, R. E., Baseler, H. A., & Morland, A. B. (2016) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12293 · Cited by 80 · see citing works
Stem cell therapy and the retina
MacLaren, R. E., & Pearson, R. A. (2007) · Eye · doi:10.1038/sj.eye.6702842 · Cited by 80 · see citing works
Cicione, R., Shivdasani, M. N., Fallon, J. B., Luu, C. D., Allen, P. J., Rathbone, G. D., Shepherd, R. K., & Williams, C. E. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036009 · Cited by 79 · see citing works
A Fully-Integrated High-Compliance Voltage SoC for Epi-Retinal and Neural Prostheses
Lo, Y., Chen, K., Gad, P. N., & Liu, W. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2013.2297695 · Cited by 80 · see citing works
- Authors
- Humayun, M. S., Weiland, J. D., Fujii, G. Y., Greenberg, R., Williamson, R., Little, J., Mech, B., Cimmarusti, V., Van Boemel, G., Dagnelie, G., & de Juan, E.
- Affiliations
- University of Southern California (US)
- Second Sight Medical Products (US)
- Johns Hopkins University (US)
- Corresponding author
- Humayun, Mark S.
- Venue
- Vision Research
- Publisher
- Elsevier BV
- Published
- 2003-11
- Volume
- 43
- Issue
- 24
- Pages
- 2573-2581
- ISSN
- 0042-6989 (ISSN-L)
- OpenAlex
- W2131773286
- Cited by
- 856
- References
- 21
- Citations by year
- 2026: 11 · 2025: 14 · 2024: 15 · 2023: 13 · 2022: 26 · 2021: 23 · 2020: 20 · 2019: 26 · 2018: 22 · 2017: 32 · 2016: 36 · 2015: 31 · 2014: 46 · 2013: 62 · 2012: 52
- FWCI
- 15.48
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Vision Research (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- National Eye Institute (R01EY012843)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
- Keywords
- retinal prosthesis, visual perception, platinum electrode, light perception, motion detection, shape recognition, chronic implantation
- MeSH terms
- Aged, Blindness, Electrodes, Implanted, Humans, Male, Photoreceptor Cells, Retina, Retinitis Pigmentosa, Visual Perception, Treatment Outcome, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review