CoChat

Ocular Higher-Order Aberrations and Contrast Sensitivity after Conventional Laser In Situ Keratomileusis

Yamane, Nayori, Miyata, Kazunori, Samejima, Tomokazu, Hiraoka, Takahiro, Kiuchi, Takahiro, Okamoto, Fumiki, Hirohara, Yoko, Mihashi, Toshifumi, Oshika, Tetsuro · 2004 · Investigative Opthalmology & Visual Science
Cited by 238

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

PURPOSE: To investigate prospectively the relation between induced changes in higher-order aberrations of the eye and changes in contrast sensitivity by conventional laser in situ keratomileusis (LASIK) for myopia. METHODS: In 200 eyes of 110 consecutive patients (mean age, 32.7 +/- 8.4 years) undergoing LASIK, ocular aberrations and contrast sensitivity function were determined before and 1 month after surgery. The amount of myopic correction was 5.2 +/- 2.8 D (range, 1.0-13.0). Ocular higher-order aberrations were measured for a 4-mm pupil using the Hartmann-Shack wavefront analyzer (KR-9000PW; Topcon, Tokyo, Japan). The root mean square (RMS) of the third- and fourth-order Zernike coefficients was used to represent coma- and spherical-like aberrations, respectively. Total higher-order aberrations were calculated as the RMS of the third- and fourth-order coefficients. Contrast sensitivity and low-contrast visual acuity were measured. From the contrast sensitivity data, the area under the log contrast sensitivity function (AULCSF) was calculated. RESULTS: LASIK significantly improved logMAR best corrected visual acuity (Wilcoxon signed-rank test, P <0.001), but significantly reduced AULCSF (P <0.001) and low-contrast visual acuity (P=0.007). Total higher-order (P <0.001), coma-like (P <0.001), and spherical-like (P <0.001) aberrations were significantly increased after LASIK. The greater the amount of achieved myopia correction was, the more the changes in contrast sensitivity function and ocular higher-order aberrations were. The induced changes in AULCSF by LASIK showed significant correlations with changes in total higher-order (Pearson r=-0.221, P=0.003), coma-like (r=-0.205, P=0.006), and spherical-like (r=-0.171, P=0.022) aberrations. The changes in logMAR low-contrast visual acuity by surgery significantly correlated with changes in total higher-order (r=0.222, P=0.003), coma-like (r=0.201, P=0.007), and spherical-like (r=0.207, P=0.005) aberrations. CONCLUSIONS: Conventional LASIK significantly increases ocular higher-order aberrations, which compromise the postoperative contrast sensitivity function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.04-0629

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 238

Metadata

Authors
Yamane, N., Miyata, K., Samejima, T., Hiraoka, T., Kiuchi, T., Okamoto, F., Hirohara, Y., Mihashi, T., & Oshika, T.
Venue
Investigative Opthalmology & Visual Science
Published
2004-11-01
Volume
45
Issue
11
Pages
3986
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2084434126
Cited by
238
References
12
FWCI
9.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ocular Higher-Order Aberrations and Contrast Sensitivity after Conventional Laser In Situ Keratomileusis. https://app.cochat.ai/papers/10.1167/iovs.04-0629
The paper
Yamane, N., Miyata, K., Samejima, T., Hiraoka, T., Kiuchi, T., Okamoto, F., Hirohara, Y., Mihashi, T., & Oshika, T. (2004). Ocular Higher-Order Aberrations and Contrast Sensitivity after Conventional Laser In Situ Keratomileusis. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.04-0629

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.