The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Axial Growth and Changes in Lenticular and Corneal Power during Emmetropization in Infants
Abstract
PURPOSE: To evaluate the contribution made by the ocular components to the emmetropization of spherical equivalent refractive error in human infants between 3 and 9 months of age. METHODS: Keratophakometry in two meridians was performed on 222 normal-birthweight infant subjects at 3 and 9 months of age. The spherical equivalent refractive error was measured by cycloplegic retinoscopy (cyclopentolate 1%). Anterior chamber depth, lens thickness, and vitreous chamber depth were measured by A-scan ultrasonography over the closed eyelid. RESULTS: Both the mean and SD for spherical equivalent refractive error decreased between 3 and 9 months of age (+2.16 +/- 1.30 D at 3 months; +1.36 +/- 1.06 D at 9 months; P < 0.0001, for the change in both mean and SD). Average ocular component change was characterized by increases in axial length, thinning, and flattening of the crystalline lens, increases in lens equivalent refractive index, and decreases in lens and corneal power. Initial refractive error was associated in a nonlinear manner with the change in refractive error (R(2) = 0.41; P < 0.0001) and with axial growth (R(2) = 0.082; P = 0.0005). Reduction in hyperopia correlated significantly with increases in axial length (R(2) = 0.16; P < 0.0001), but not with changes in corneal and lenticular power. Decreases in lenticular and corneal power were associated with axial elongation (R(2) = 0.40, R(2) = 0.12, respectively; both P < 0.0001). CONCLUSIONS: Modulation in the amount of axial growth in relation to initial refractive error appeared to be the most influential factor in emmetropization of spherical equivalent refractive error. The associations between initial refractive error, subsequent axial growth, and change in refractive error were consistent with a visual basis for emmetropization. The cornea and crystalline lens lost substantial amounts of dioptric power in this phase of growth, but neither appeared to play a significant role in emmetropization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accommodation, refractive error and eye growth in chickens
Schaeffel, F., Glasser, A., & Howland, H. C. (1988) · Vision Research · doi:10.1016/0042-6989(88)90113-7 · Cited by 689
Choroidal and scleral mechanisms of compensation for spectacle lenses in chicks
Wildsoet, C., & Wallman, J. (1995) · Vision Research · doi:10.1016/0042-6989(94)00233-c · Cited by 634
Moving the retina: Choroidal modulation of refractive state
Wallman, J., Wildsoet, C., Xu, A., Gottlieb, M. D., Nickla, D. L., Marran, L., Krebs, W., & Christensen, A. M. (1995) · Vision Research · doi:10.1016/0042-6989(94)e0049-q · Cited by 587
The role of optical defocus in regulating refractive development in infant monkeys
Smith III, E. L., & Hung, L.-F. (1999) · Vision Research · doi:10.1016/s0042-6989(98)00229-6 · Cited by 403
Wallman, J., & I. Adams, J. (1987) · Vision Research · doi:10.1016/0042-6989(87)90027-7 · Cited by 396
Refractive plasticity of the developing chick eye
Irving, E. L., Sivak, J. G., & CALLENDER, M. G. (1992) · Ophthalmic and Physiological Optics · doi:10.1016/0275-5408(92)90175-v · Cited by 324
The repeatability of measurement of the ocular components.
Zadnik, K., Mutti, D. O., & Adams, A. J. (1992) · PubMed · Cited by 319
Self-citationActive emmetropization ? evidence for its existence and ramifications for clinical practice
Wildsoet, C. F. (1997) · Ophthalmic and Physiological Optics · doi:10.1016/s0275-5408(97)00003-3 · Cited by 279
Optical and structural development of the crystalline lens in childhood
(1998) · Journal of American Association for Pediatric Ophthalmology and Strabismus · doi:10.1016/s1091-8531(98)90096-9 · Cited by 203
Muscarinic antagonist effects on experimental chick myopia
Stone, R. A., Lin, T., & Laties, A. M. (1991) · Experimental Eye Research · doi:10.1016/0014-4835(91)90027-c · Cited by 192
Cited by
Baird, P. N., Saw, S.-M., Lanca, C., Guggenheim, J. A., Smith III, E. L., Zhou, X., Matsui, K.-O., Wu, P.-C., Sankaridurg, P., Chia, A., et al. (2020) · Nature Reviews Disease Primers · doi:10.1038/s41572-020-00231-4 · Cited by 838
Consortium for Refractive Error and Myopia (CREAM), Verhoeven, V. J. M., The Diabetes Control and Complications Trial/Epidemiology of Diabetes Interventions and Complications (DCCT/EDIC) Research Group, Wellcome Trust Case Control Consortium 2 (WTCCC2), The Fuchs' Genetics Multi-Center Study Group, Hysi, P. G., Wojciechowski, R., Fan, Q., Guggenheim, J. A., Höhn, R., et al. (2013) · Nature Genetics · doi:10.1038/ng.2554 · Cited by 487
IMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
Self-citationBrennan, N. A., Toubouti, Y. M., Cheng, X., & Bullimore, M. A. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100923 · Cited by 355
McCullough, S. J., O’Donoghue, L., & Saunders, K. J. (2016) · PLOS ONE · doi:10.1371/journal.pone.0146332 · Cited by 147
Salehi, M. A., Nowroozi, A., Gouravani, M., Mohammadi, S., & Arevalo, J. F. (2022) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2021.07.007 · Cited by 46
Metadata
- Authors
- Mutti, D. O., Mitchell, G. L., Jones, L. A., Friedman, N. E., Frane, S. L., Lin, W. K., Moeschberger, M. L., & Zadnik, K.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2005-09-01
- Volume
- 46
- Issue
- 9
- Pages
- 3074
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2078231330
- Cited by
- 404
- References
- 18
- FWCI
- 5.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.