The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Changes in Collagen Orientation and Distribution in Keratoconus Corneas
Abstract
PURPOSE: To map the collagen orientation and relative distribution of collagen fibrillar mass in keratoconus corneal buttons. METHODS: Structural analysis was performed by obtaining synchrotron x-ray scattering patterns across the samples at 0.25-mm intervals. The patterns were analyzed to produce two-dimensional maps of the orientation of the lamellae and of the distribution of total and preferentially aligned lamellae. RESULTS: Compared with normal corneas, in keratoconus the gross organization of the stromal lamellae was dramatically changed, and the collagen fibrillar mass was unevenly distributed, particularly around the presumed apex of the cone. CONCLUSIONS: The development of keratoconus involves a high degree of inter- and probably intralamellar displacement and slippage that leads to thinning of the central cornea and associated changes in corneal curvature. This slippage may be promoted by a loss of cohesive forces and mechanical failure in regions where lamellae bifurcate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
X-Ray Scattering Used to Map the Preferred Collagen Orientation in the Human Cornea and Limbus
Aghamohammadzadeh, H., Newton, R. H., & Meek, K. M. (2004) · Structure · doi:10.1016/j.str.2004.01.002 · Cited by 233
Self-citationInterlacing and cross-angle distribution of collagen lamellae in the human cornea
Radner, W., Zehetmayer, M., Aufreiter, R., & Mallinger, R. (1998) · Cornea · doi:10.1097/00003226-199809000-00012 · Cited by 153
A synchrotron X-ray diffraction study of bovine cornea stained with cupromeronic blue
Meek, K. M., Elliott, G. F., & Nave, C. (1986) · Collagen and Related Research · doi:10.1016/s0174-173x(86)80026-7 · Cited by 46
Self-citation
Cited by
Keratoconus: an inflammatory disorder?
Galvis, V, Sherwin, T., Tello, A., Merayo, J., Barrera, R., & Acera, A. (2015) · Eye · doi:10.1038/eye.2015.63 · Cited by 395
The pathogenesis of keratoconus
Davidson, A. E., Hayes, S., Hardcastle, A. J., & Tuft, S. J. (2014) · Eye · doi:10.1038/eye.2013.278 · Cited by 360
Self-citationPolarization sensitive optical coherence tomography in the human eye
Pircher, M., Hitzenberger, C. K., & Schmidt-Erfurth, U. (2011) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2011.06.003 · Cited by 288
Second-Harmonic Imaging Microscopy of Normal Human and Keratoconus Cornea
Morishige, N., Wahlert, A. J., Kenney, M. C., Brown, D. J., Kawamoto, K., Chikama, T.-I., Nishida, T., & Jester, J. V. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-1177 · Cited by 272
Abahussin, M., Hayes, S., Knox Cartwright, N. E., Kamma-Lorger, C. S., Khan, Y., Marshall, J., & Meek, K. M. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3669 · Cited by 162
Self-citation
Metadata
- Authors
- Meek, K. M., Tuft, S. J., Huang, Y., Gill, P. S., Hayes, S., Newton, R. H., & Bron, A. J.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2005-06-01
- Volume
- 46
- Issue
- 6
- Pages
- 1948
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2139139663
- Cited by
- 509
- References
- 3
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.