Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 272

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Second-Harmonic Imaging Microscopy of Normal Human and Keratoconus Cornea

Open access
Morishige, Naoyuki, Wahlert, Andrew J., Kenney, M. Cristina, Brown, Donald J., Kawamoto, Koji, Chikama, Tai-ichiro, Nishida, Teruo, Jester, James V.·2007·Investigative Opthalmology & Visual Science

Abstract

PURPOSE: The purpose of this study was to evaluate the ability of second-harmonic imaging to identify differences in corneal stromal collagen organization between normal human and keratoconus corneas. METHODS: Six normal corneas from eye bank donors and 13 corneas of patients with keratoconus, obtained after penetrating keratoplasty were examined. A femtosecond titanium-sapphire laser with 800-nm output was used to generate second-harmonic signals collected at 400 nm from central and paracentral corneal tissue blocks. Three-dimensional (3-D) data sets were collected and reconstructed to evaluate the location and orientation of stromal collagen lamellae. RESULTS: Imaging of second-harmonic signals combined with 3-D reconstruction of the normal cornea identified a high degree of lamellar interweaving, particularly in the anterior cornea. Of note was the detection of lamellae that inserted into Bowman's layer and were oriented transverse to the corneal surface, penetrating posteriorly approximately 120 mum. In keratoconus corneas, imaging second-harmonic signals identified less lamellar interweaving and a marked reduction or loss of lamellae inserting into Bowman's layer in 12 of 13 cases, particularly in regions associated with cone development without breaks in Bowman's layer or scarring. CONCLUSIONS: Compared with normal adult corneas, marked abnormalities were detected in the organization of the anterior corneal collagen lamellae of keratoconus corneas by second harmonic imaging. These structural abnormalities are consistent with the known changes in collagen organization and biomechanical strength of keratoconus.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.06-1177

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 20 references

Cited by

See all 272

Metadata

Authors
Morishige, N., Wahlert, A. J., Kenney, M. C., Brown, D. J., Kawamoto, K., Chikama, T.-I., Nishida, T., & Jester, J. V.
Venue
Investigative Opthalmology & Visual Science
Published
2007-03-01
Volume
48
Issue
3
Pages
1087
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2025937300
Cited by
272
References
20
FWCI
12.08
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Second-Harmonic Imaging Microscopy of Normal Human and Keratoconus Cornea. https://app.cochat.ai/papers/10.1167/iovs.06-1177
The paper
Morishige, N., Wahlert, A. J., Kenney, M. C., Brown, D. J., Kawamoto, K., Chikama, T.-I., Nishida, T., & Jester, J. V. (2007). Second-Harmonic Imaging Microscopy of Normal Human and Keratoconus Cornea. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.06-1177

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.