Cited by 162Corneal surgery and disordersCorneal Surgery and TreatmentsOcular Surface and Contact Lens

3D Collagen Orientation Study of the Human Cornea Using X-ray Diffraction and Femtosecond Laser Technology

Open access
Abahussin, Mohammad, Hayes, Sally, Knox Cartwright, Nathaniel E., Kamma-Lorger, Christina S., Khan, Yasir, Marshall, John, Meek, Keith M.·2009·Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To study the distribution and predominant orientations of fibrillar collagen at different depths throughout the entire thickness of the human cornea. This information will form the basis of a full three-dimensional reconstruction of the preferred orientations of corneal lamellae. METHODS: Femtosecond laser technology was used to delaminate the central zones of five human corneas into three separate layers (anterior, mid, and posterior stroma), each with predetermined thicknesses. Wide-angle x-ray diffraction was used to study the gross collagen fibril orientation and distribution within each layer. RESULTS: The middle and posterior parts of the human cornea demonstrated a preferential orthogonal arrangement of collagen fibrils, directed along the superior-inferior and nasal-temporal meridians, with an increase in the number of lamellae toward the periphery. However, the anterior cornea (33% of total corneal thickness) showed no systematic preferred lamellar orientation. CONCLUSIONS: In the posterior two thirds of the human cornea, collagen lies predominantly in the vertical and horizontal meridians (directed toward the four major rectus muscles), whereas collagen in the anterior third of the cornea is more isotropic. The predominantly orthogonal arrangement of collagen in the mid and posterior stroma may help to distribute strain in the cornea by allowing it to withstand the pull of the extraocular muscles, whereas the more isotropic arrangement in the anterior cornea may play an important role in the biomechanics of the cornea by resisting intraocular pressure while at the same time maintaining corneal curvature.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.09-3669

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Across the anterior stroma, lamellae are highly interwoven and randomly directed when observed en face.

    “Across the anterior stroma, lamellae are highly interwoven (Radner et al., 1998) and randomly directed when observed en face (Abahussin et al., 2009).”

    From Corneal structure and transparency (2015) · cites this paper as Abahussin et al., 2009

  • Collagen lamellae in the deeper stroma have preferred directions that appear to be close to the inferior-superior and nasal-temporal directions.

    “Collagen lamellae in the deeper stroma (Fig. 1a) have preferred directions, which appear to be close to the inferior-superior and nasal-temporal directions (Meek et al., 1987, Aghamohammadzadeh et al., 2004, Abahussin et al., 2009, Kamma-Lorger et al., 2010).”

    From Corneal structure and transparency (2015) · cites this paper as Abahussin et al., 2009

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 32

  1. Hogan MJ, Alvarado JA, Weddell JE. The cornea. Histology of the Human Eye. Philadelphia, W.B. Saunders Company. 1971:55-111.
  2. Maurice DM. The cornea and sclera. In: Davson H. The Eye. London: Academic Press; 1969:489 -600.
  3. Radner W, Zehetmayer M, Aufreiter R, Mallinger R. Interlacing and cross-angle distribution of collagen lamellae in the human cornea. Cornea. 1998;17:537-543.
  4. Newton RH, Meek KM. The integration of the corneal and limbal fibrils in the human eye. Biophys J. 1998;75:2508 -2512.
  5. Quantock AJ, Meek KM, Chakravarti S. An X-ray diffraction inves- tigation of corneal structure in lumican-deficient mice. Invest Oph- thalmol Vis Sci. 2001;42:1750 -1756.
  6. Meek KM, Dennis S, Khan S. Changes in the refractive index of the stroma and its extrafibrillar matrix when the cornea swells. Bio- phys J. 2003;85:2205-2212.
  7. Farrell R, McCally R. Corneal transparency. In: Albert D, Jakobiec F. Principles and Practice of Ophthalmology. Philadelphia: Saunders; 2000:629 -643.
  8. Kokott W. Ubermechanisch-funktionelle strikturen des auges. Al- brecht von Graefes Arch Ophthalmol. 1938;138:424 -485.
  9. Meek KM, Blamires T, Elliott GF, Gyi TJ, Nave C. The organisation of collagen fibrils in the human corneal stroma: a synchrotron X-ray diffraction study. Curr Eye Res. 1987;6:841-846.
  10. Komai Y, Ushiki T. The three-dimensional organization of collagen fibrils in the human cornea and sclera. Invest Ophthalmol Vis Sci. 1991;32:2244 -2258.
  11. Daxer A, Fratzl P. Collagen fibril orientation in the human corneal stroma and its implication in keratoconus. Invest Ophthalmol Vis Sci. 1997;38:121-129.
  12. Misson GP. Circular polarization biomicroscopy: a method for determining human corneal stromal lamellar organization in vivo. Ophthalmic Physiol Opt. 2007;27:256 -264.
  13. Holmes DF, Gilpin CJ, Baldock C, Ziese U, Koster AJ, Kadler KE. Corneal collagen fibril structure in three dimensions: structural insights into fibril assembly, mechanical properties, and tissue organization. Proc Natl Acad Sci U S A. 2008;98:7307-7312.
  14. Newton RH, Meek KM. Circumcorneal annulus of collagen fibrils in the human limbus. Invest Ophthalmol Vis Sci. 1998;39:1125- 1134.
  15. Boote C, Dennis S, Meek KM. Spatial mapping of collagen fibril organisation in primate cornea: an X-ray diffraction investigation. J Struct Biol. 2004;146:359 -367.
  16. Connon CJ, Meek KM. Organization of corneal collagen fibrils during the healing of trephined wounds in rabbits. Wound Repair Regen. 2003;11:71-78.
  17. Boote C, Dennis S, Huang Y, Quantock AJ, Meek KM. Lamellar orientation in human cornea in relation to mechanical properties. J Struct Biol. 2005;149:1-6.
  18. Boote C, Hayes S, Abahussin M, Meek KM. Mapping collagen organization in the human cornea: left and right eyes are structur- ally distinct. Invest Ophthalmol Vis Sci. 2006;47:901-908.
  19. Meek KM, Quantock AJ. The use of X-ray scattering techniques to determine corneal ultrastructure. Prog Retin Eye Res. 2001;20:95- 137.
  20. Meek KM, Tuft SJ, Huang Y, et al. Changes in collagen orientation and distribution in keratoconus corneas. Invest Ophthalmol Vis Sci. 2005;46:1948 -1956.
  21. Freund DE, McCally RL, Farrell RA, Cristol SM, L'Hernault NL, Edelhauser HF. Ultrastructure in anterior and posterior stroma of perfused human and rabbit corneas: relation to transparency. In- vest Ophthalmol Vis Sci. 1995;36:1508 -1523.
  22. Daxer A, Misof K, Grabner B, Ettl A, Fratzl P. Collagen fibrils in the human corneal stroma: structure and aging. Invest Ophthalmol Vis Sci. 1998;39:644 -648.
  23. Meek KM, Fullwood NJ. Corneal and scleral collagens-a microsco- pist's perspective. Micron. 2001;32:261-272.
  24. Kezirian GM, Stonecipher KG. Comparison of the IntraLase fem- tosecond laser and mechanical keratomes for laser in situ kerato- mileusis. J Cataract Refract Surg. 2004;30:971-978.
  25. Holzer MP, Rabsilber TM, Auffarth GU. Femtosecond laser-assisted corneal flap cuts: morphology, accuracy and histopathology. In- vest Ophthalmology Vis Sci. 2006;47:2828 -2831.
  26. Sarayba MA, Ignacio TS, Tran DB, Binder PS. A 60 kHz IntraLase femtosecond laser creates a smoother LASIK stromal bed surface compared to a Zyoptix XP mechanical microkeratome in human donor eyes. J Refract Surg. 2007;23:331-337.
  27. Davson H. The Eye. Vol 1b. 3rd ed. New York: Academic Press; 1984.
  28. Klyce SD, Beuerman RW. Structure and function of the cornea. In: Kaufmann HE, ed. The Cornea. New York: Churchill Livingstone; 1988:3-28.
  29. Morishige N, Wahlert AJ, Kenney MC, et al. Second-harmonic imaging microscopy of normal human and keratoconus cornea. Invest Ophthalmol Vis Sci. 2007;48:1087-1094.
  30. ElSheikh A, Brown M, Alhasso D, Rama P, Campanelli M, Garway- Heath D. Experimental assessment of corneal anisotropy. J Refract Surg. 2008;24:178 -187.
  31. Pinsky PM, Van der Heide D, Chernyak D. Computational model- ling of mechanical anisotropy in the cornea and sclera. J Cataract Refract Surg. 2005;31:136 -145.
  32. Lanchares E, Calvo B, Cristobal JA, Doblare M. Finite element simulation of arcuates for astigmatism correction. J Biomech. 2008;41:797-805.

Cited by

Sorted by citations

Authors
Abahussin, M., Hayes, S., Knox Cartwright, N. E., Kamma-Lorger, C. S., Khan, Y., Marshall, J., & Meek, K. M.
Affiliations
  • Cardiff University (GB)
  • The Rayne Institute, St. Thomas' Hospital, London, United Kingdom.
  • From the School of Optometry and Vision Sciences, Cardiff University, Cardiff, United Kingdom; and
  • St Thomas' Hospital (GB)
Venue
Investigative Opthalmology & Visual Science
Published
2009-11-01
Volume
50
Issue
11
Pages
5159
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2035794738
Cited by
162
References
2
Citations by year
2026: 5 · 2025: 10 · 2024: 5 · 2023: 7 · 2022: 7 · 2021: 10 · 2020: 13 · 2019: 10 · 2018: 12 · 2017: 12 · 2016: 10 · 2015: 11 · 2014: 9 · 2013: 17 · 2012: 9
FWCI
5.50
Type
journal article
Language
en
Open access
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion)
  • PubMed (publishedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
  • UCL Discovery (University College London) (submittedVersion)
Funders
Cardiff University
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Ocular Surface and Contact Lens
Keywords
human cornea, corneal stroma, corneal lamellae, corneal biomechanics, intraocular pressure, corneal curvature, anterior cornea, posterior cornea, wide-angle X-ray diffraction
MeSH terms
Cornea, Humans, Lasers, Molecular Conformation, X-Ray Diffraction, Fibrillar Collagens

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review