The DOI matches its Crossref record.
Peripheral Vision Can Influence Eye Growth and Refractive Development in Infant Monkeys
Open accessAbstract
PURPOSE: Given the prominence of central vision in humans, it has been assumed that visual signals from the fovea dominate emmetropization. The purpose of this study was to examine the impact of peripheral vision on emmetropization. METHODS: Bilateral, peripheral form deprivation was produced in 12 infant monkeys by rearing them with diffusers that had either 4- or 8-mm apertures centered on the pupils of each eye, to allow 24 degrees or 37 degrees of unrestricted central vision, respectively. At the end of the lens-rearing period, an argon laser was used to ablate the fovea in one eye of each of seven monkeys. Subsequently, all the animals were allowed unrestricted vision. Refractive error and axial dimensions were measured along the pupillary axis by retinoscopy and A-scan ultrasonography, respectively. Control data were obtained from 21 normal monkeys and 3 infants reared with binocular plano lenses. RESULTS: Nine of the 12 treated monkeys had refractive errors that fell outside the 10th- and 90th-percentile limits for the age-matched control subjects, and the average refractive error for the treated animals was more variable and significantly less hyperopic/more myopic (+0.03 +/- 2.39 D vs. +2.39 +/- 0.92 D). The refractive changes were symmetric in the two eyes of a given animal and axial in nature. After lens removal, all the treated monkeys recovered from the induced refractive errors. No interocular differences in the recovery process were observed in the animals with monocular foveal lesions. CONCLUSIONS: On the one hand, the peripheral retina can contribute to emmetropizing responses and to ametropias produced by an abnormal visual experience. On the other hand, unrestricted central vision is not sufficient to ensure normal refractive development, and the fovea is not essential for emmetropizing responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hiraoka, T., Kakita, T., Okamoto, F., Takahashi, H., & Oshika, T. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8453 · Cited by 488
IMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
Self-citationRelative peripheral hyperopic defocus alters central refractive development in infant monkeys
Smith, E. L., Hung, L.-F., & Huang, J. (2009) · Vision Research · doi:10.1016/j.visres.2009.07.011 · Cited by 444
Self-citationEffect of Dual-Focus Soft Contact Lens Wear on Axial Myopia Progression in Children
Anstice, N. S., & Phillips, J. R. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.10.035 · Cited by 422
Influence of Overnight Orthokeratology on Axial Elongation in Childhood Myopia
Kakita, T., Hiraoka, T., & Oshika, T. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5485 · Cited by 414
Myopia Control with Orthokeratology Contact Lenses in Spain: Refractive and Biometric Changes
Santodomingo-Rubido, J., Villa-Collar, C., Gilmartin, B., & Gutiérrez-Ortega, R. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8005 · Cited by 334
Bao, J., Huang, Y., Li, X., Yang, A., Zhou, F., Wu, J., Wang, C., Li, Y., Lim, E. W., Spiegel, D. P., et al. (2022) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2022.0401 · Cited by 304
Optical quality of emmetropic and myopic eyes in the periphery measured with high-angular resolution
Jaeken, B., & Artal, P. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8993 · Cited by 75
Myopia and peripheral ocular aberrations
Mathur, A., Atchison, D. A., & Charman, W. N. (2009) · Journal of Vision · doi:10.1167/9.10.15 · Cited by 53
Metadata
- Authors
- Smith, E. L., Kee, C.-S., Ramamirtham, R., Qiao-Grider, Y., & Hung, L.-F.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2005-11-01
- Volume
- 46
- Issue
- 11
- Pages
- 3965
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1976175223
- Cited by
- 523
- References
- 0
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.