CoChat

Intraretinal Oxygen Distribution in the Monkey Retina and the Response to Systemic Hyperoxia

Yu, Dao-Yi, Cringle, Stephen J., Su, Er-Ning · 2005 · Investigative Opthalmology & Visual Science

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

PURPOSE: To measure the intraretinal oxygen distribution and consumption in the fovea, the parafovea, and the inferior retina in the monkey eye and determine the influence of graded systemic hyperoxia. METHODS: Oxygen sensitive microelectrodes were used to measure the oxygen tension as a function of depth through the retina in anesthetized monkeys (n = 8) under normoxic and hyperoxic conditions. Oxygen consumption rates in the avascular regions of retina were determined by fitting the oxygen profiles to established oxygen consumption models. RESULTS: Under normoxic conditions, in the foveal area, the intraretinal oxygen distribution reflected the absence of retinal capillaries and the predominantly choroidal origin of retinal oxygenation. A similar shape of oxygen distribution was seen in the parafoveal retina with the addition of local perturbations in the inner retina attributed to the presence of retinal capillaries. In the inferior retina the same general shape was found. Oxygen consumption in the outer retina was higher in the parafoveal region, and the minimum oxygen tension was lower. During hyperoxia, choroidal oxygen levels in all areas increased dramatically, but the increase in oxygen tension in the inner retina was much less. The avascular nature of the foveal area allowed oxygen consumption analysis of both the inner and outer retina and showed that inner retinal oxygen consumption increased significantly during hyperoxic ventilation to a level equivalent to that of the outer retina. CONCLUSIONS: In the outer retina of the monkey the P(O2) minimum is lower, and the oxygen consumption rate is higher in the parafoveal region. During systemic hyperoxia, outer retinal oxygen consumption is unaffected, but in the foveal area, total oxygen consumption increases. This regulation of oxygen consumption in the monkey retina is comparable to that reported in lower mammals and may represent an important mechanism in retinal homeostasis.

Overview

Integrity signals

Registry

Crossref · 10.1167/iovs.05-0694

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 24 references

Cited by

See all 141

Metadata

Authors
Yu, D.-Y., Cringle, S. J., & Su, E.-N.
Affiliations
The University of Western Australia (AU)
Venue
Investigative Opthalmology & Visual Science
Published
2005-12-01
Volume
46
Issue
12
Pages
4728
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2056265720
Cited by
133
References
24
Citations by year
2026: 1 · 2025: 3 · 2024: 8 · 2023: 5 · 2022: 14 · 2021: 8 · 2020: 10 · 2019: 8 · 2018: 3 · 2017: 9 · 2016: 6 · 2015: 7 · 2014: 4 · 2013: 7 · 2012: 10
FWCI
3.05
Type
journal article
Language
en
Open access
closed
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion)
  • PubMed (publishedVersion)
  • UWA Profiles and Research Repository (UWA) (submittedVersion)
Funders
Fudan University
Topics
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
  • Health Sciences › Medicine › Ophthalmology › Retinal Development and Disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
Keywords
retinal oxygen consumption, fovea, parafovea, retinal capillaries, oxygen partial pressure, retinal homeostasis, oxygen microelectrodes, monkey retina
MeSH terms
Animals, Blood Gas Analysis, Blood Pressure, Macaca mulatta, Microelectrodes, Oxygen, Oxygen Consumption, Partial Pressure, Retina, Ion-Selective Electrodes, Hyperoxia

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.