The DOI matches its Crossref record.
Noninvasive Measurement of Rodent Intraocular Pressure with a Rebound Tonometer
Abstract
PURPOSE: The present study evaluated the applicability of a rebound tonometer in measuring intraocular pressure (IOP) in rats and mice. METHODS: The accuracy of the TonoLab rebound tonometer was determined in cannulated mouse and rat eyes. IOP was manipulated by changing reservoir height, and tonometer pressure readings were recorded by an independent observer. IOP values were recorded in conscious Wistar rats and in four different strains of mice. The effects of anesthesia on IOP were evaluated in two different strains of mice. RESULTS: The IOP readings generated by the rebound tonometer correlated very well with the actual pressure in the eye. In rats, this linear correlation had a slope of 0.96 +/- 0.05 (mean +/- SEM, n = 4) and a Y-intercept of -2.1 +/- 1.2. In mice, the slope was 0.99 +/- 0.05 (n = 3), and the Y-intercept was 0.8 +/- 1.4. Using this method, the resting IOP of conscious male Wistar rats was observed to be 18.4 +/- 0.1 mm Hg (n = 132). In mice, strain differences in IOP were detected. Baseline IOP values in Balb/c, C57-BL/6, CBA, and 11- to 12-month-old DBA/2J mice were 10.6 +/- 0.6, 13.3 +/- 0.3, 16.4 +/- 0.3, and 19.3 +/- 0.4 mm Hg (n = 12), respectively. In separated studies, anesthesia lowered IOP from 14.3 +/- 0.9 to 9.2 +/- 0.5 mm Hg (n = 8) in C57-BL/6 mice, and from 16.6 +/- 0.4 to 9.4 +/- 0.6 mm Hg (n = 10) in CBA mice. CONCLUSIONS: The rebound tonometer was easy to use and accurately measured IOP in rats and mice. This technique, together with advances in genetic and other biological studies in rodents, will be valuable in the further understanding of the etiology and pathology of glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Rho Kinase (ROCK) Inhibitors and Their Therapeutic Potential
Feng, Y., LoGrasso, P. V., Defert, O., & Li, R. (2016) · Journal of Medicinal Chemistry · doi:10.1021/acs.jmedchem.5b00683 · Cited by 378
Optic nerve astrocyte reactivity protects function in experimental glaucoma and other nerve injuries
Sun, D., Moore, S., & Jakobs, T. C. (2017) · Journal of Experimental Medicine · doi:10.1084/jem.20160412 · Cited by 130
SPARC-null Mice Exhibit Lower Intraocular Pressures
Haddadin, R. I., Oh, D.-J., Kang, M. H., Filippopoulos, T., Gupta, M., Hart, L., Sage, E. H., & Rhee, D. J. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2489 · Cited by 71
“The validation experiment was repeated to confirm that our IOP measurement technique was consistent with the commercial calibration.(39) In brief, WT and SPARC-null eyes were cannulated through the temporal limbus with a 30-gauge needle attached to a water reservoir and pressure transducer.”
Method
Metadata
- Authors
- Wang, W.-H., Millar, J. C., Pang, I.-H., Wax, M. B., & Clark, A. F.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2005-12-01
- Volume
- 46
- Issue
- 12
- Pages
- 4617
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2047510146
- Cited by
- 227
- References
- 0
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.