SPARC-null Mice Exhibit Lower Intraocular Pressures
The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
PURPOSE: SPARC is a matricellular protein that is highly expressed in remodeling tissues, including the trabecular meshwork and ciliary body. The hypothesis for the study was that SPARC contributes to the regulation of intraocular pressure (IOP). The IOPs of SPARC-null mice, their corresponding wild-type (WT), and heterozygous animals were compared. METHODS: Diurnal and nocturnal IOPs of C57Bl/6x129SvJ WT, SPARC-null, and heterozygous mice were measured. Fluorophotometric measurements were made to assess aqueous turnover. Central corneal thickness (CCT) was measured using histology, ultrasound biomicroscopy, and optical coherence tomography. Iridocorneal angles were examined using light microscopy (LM). RESULTS: During the day, the mean IOP of SPARC-null mice (n = 142, 16.9 +/- 2.4 mm Hg) was lower than that of both WT mice (n = 104, 19.9 +/- 2.9 mm Hg; P < 10(-12)), and heterozygotes (n = 38, 19.3 +/- 2.5 mm Hg; P < 10(-4)). At night, SPARC-null mice also exhibited a blunted increase in IOP in comparison to WT and heterozygous mice. CCTs were not significantly different between WT and SPARC-null mice. Heterozygous mice tended to have thicker corneas (3.4%). Fluorophotometric measurements suggest that aqueous turnover rates in SPARC-null mice are equal to if not greater than rates in WT mice. LM of the SPARC-null iridocorneal angle revealed morphology that is indistinguishable from WT. CONCLUSIONS: SPARC-null mice have lower IOPs than do their WT counterparts with equal CCTs. The rate of aqueous turnover suggests that the mechanism is enhanced outflow resistance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the SPARC protein, whose expression inhibition in TMCs or knockout in mice has been associated with enhanced aqueous drainage [ 119 , 120 ]”
From MAPK Pathways in Ocular Pathophysiology: Potential Therapeutic Drugs and Challenges (2023) · cites this paper as [119]
Citations
Cites
Klein, B. E. K., Klein, R., Sponsel, W. E., Franke, T., Cantor, L. B., Martone, J., & Menage, M. J. (1992) · Ophthalmology · doi:10.1016/s0161-6420(92)31774-9 · Cited by 967
Racial Variations in the Prevalence of Primary Open-angle Glaucoma: The Baltimore Eye Survey
Tielsch, J. M. (1991) · JAMA · doi:10.1001/jama.1991.03470030069026 · Cited by 879
The Barbados Eye Study: Prevalence of Open Angle Glaucoma
Leske, M. C. (1994) · Archives of Ophthalmology · doi:10.1001/archopht.1994.01090180121046 · Cited by 685
Experimental Aqueous Perfusion in Enucleated Human Eyes
GRANT, W. M. (1963) · Archives of Ophthalmology · doi:10.1001/archopht.1963.00960040789022 · Cited by 538 · cited 1×
“The relatively elevated IOP of open-angle glaucoma is caused by impaired aqueous drainage through the trabecular meshwork (TM) (conventional pathway).(5) The secondary pathway for aqueous drainage, the uveoscleral pathway, also demonstrates morphologic changes in the ciliary body (CB) stroma of glaucomatous eyes, simi…”
BackgroundSPARC, a Matricellular Glycoprotein with Important Biological Functions
Yan, Q., & Sage, E. H. (1999) · Journal of Histochemistry & Cytochemistry · doi:10.1177/002215549904701201 · Cited by 379 · cited 1×
“SPARC (secreted protein, acidic and rich in cysteine), a member of the matricellular family of proteins, modulates cellular interactions with ECM during embryogenesis and in adult tissues that continue to remodel.(12,13) SPARC has also been implicated in several conditions in which fibrosis and altered ECM deposition…”
BackgroundSelf-citationOsteopenia and decreased bone formation in osteonectin-deficient mice
Delany, A. M., Amling, M., Priemel, M., Howe, C., Baron, R., & Canalis, E. (2000) · Journal of Clinical Investigation · doi:10.1172/jci7039 · Cited by 330
Effect of matrix metalloproteinases activity on outflow in perfused human organ culture.
Bradley, J. M., Vranka, J. A., Colvis, C. M., Conger, D. M., Alexander, J. P., Fisk, A. S., Samples, J. R., & Acott, T. S. (1998) · PubMed · Cited by 328
SPARC and tumor growth: Where the seed meets the soil?
Framson, P. E., & Sage, E. H. (2004) · Journal of Cellular Biochemistry · doi:10.1002/jcb.20091 · Cited by 249
Self-citationProstaglandins increase matrix metalloproteinase release from human ciliary smooth muscle cells.
Weinreb, R. N., Kashiwagi, K., Kashiwagi, F., Tsukahara, S., & Lindsey, J. D. (1997) · PubMed · Cited by 249
Bradshaw, A. D., Puolakkainen, P., Wight, T. N., Helene Sage, E., Dasgupta, J., & Davidson, J. M. (2003) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2003.12241.x · Cited by 238
Self-citation
Cited by
Vranka, J. A., Kelley, M. J., Acott, T. S., & Keller, K. E. (2015) · Experimental Eye Research · doi:10.1016/j.exer.2014.07.014 · Cited by 393
“X, hevin and osteopontin, have been investigated (Chatterjee et al., 2014; Chowdhury et al., 2011; Haddadin et al., 2009; Haddadin et al., 2012; Kang et al., 2011; Keller et al., 2013).”
BackgroundAqueous outflow - A continuum from trabecular meshwork to episcleral veins
Carreon, T., van der Merwe, E., Fellman, R. L., Johnstone, M., & Bhattacharya, S. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.12.004 · Cited by 312
“The outflow increase occurs uniformly 360 degrees around the TM circumference (Haddadin et al., 2009; Swaminathan et al., 2013).”
Inducible rodent models of glaucoma
Pang, I.-H., & Clark, A. F. (2020) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.100799 · Cited by 158
Pathogenesis of glaucoma: Extracellular matrix dysfunction in the trabecular meshwork‐A review
Keller, K. E., & Peters, D. M. (2022) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.14027 · Cited by 137
“While there was no gross morphological differences in the irideocorneal angle tissue between SPARC knockout and wild-type mice, SPARC-null mice had significantly lower IOPs ( 3 mmHg) than wild-type littermates and higher outflow facility through the conventional pathway.(152,153) Fluorescent tracer studies showed a mo…”
BackgroundVillarreal, G., Oh, D.-J., Kang, M. H., & Rhee, D. J. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-6165 · Cited by 109
Self-citation
Metadata
- Authors
- Haddadin, R. I., Oh, D.-J., Kang, M. H., Filippopoulos, T., Gupta, M., Hart, L., Sage, E. H., & Rhee, D. J.
- Affiliations
- Massachusetts Eye and Ear Infirmary (US)
- Benaroya Research Institute (US)
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2009-08-01
- Volume
- 50
- Issue
- 8
- Pages
- 3771
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2154381096
- Cited by
- 71
- References
- 53
- Citations by year
- 2026: 1 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 2 · 2019: 3 · 2018: 1 · 2017: 4 · 2016: 6 · 2015: 7 · 2014: 10 · 2013: 8 · 2012: 4
- FWCI
- 5.42
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Investigative Ophthalmology & Visual Science (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Scheme for Promotion of Academic and Research Collaboration
- National Eye Institute (EY014104, P30EY014104)
- Topics
- Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
- Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Keywords
- SPARC, intraocular pressure, SPARC-null mice, trabecular meshwork, ciliary body, aqueous humor outflow resistance, central corneal thickness, anterior chamber angle, diurnal IOP variation, glaucoma
- MeSH terms
- Animals, Anterior Eye Segment, Aqueous Humor, Circadian Rhythm, Cornea, Female, Intraocular Pressure, Male, Mice, Inbred C57BL, Tonometry, Ocular, Fluorophotometry, Osteonectin, Gene Deletion, Mice, Knockout, Microscopy, Acoustic, Tomography, Optical Coherence, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: SPARC-null Mice Exhibit Lower Intraocular Pressures. https://app.cochat.ai/papers/10.1167/iovs.08-2489
- The paper
- Haddadin, R. I., Oh, D.-J., Kang, M. H., Filippopoulos, T., Gupta, M., Hart, L., Sage, E. H., & Rhee, D. J. (2009). SPARC-null Mice Exhibit Lower Intraocular Pressures. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.08-2489
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.