Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 994

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Visual Acuities “Hand Motion” and “Counting Fingers” Can Be Quantified with the Freiburg Visual Acuity Test

Schulze-Bonsel, Kilian, Feltgen, Nicolas, Burau, Hermann, Hansen, Lutz, Bach, Michael·2006·Investigative Opthalmology & Visual Science

Abstract

PURPOSE: The visual acuity (VA) of patients with very low vision is classified using the semiquantitative scale "counting fingers" (CF), "hand motion" (HM), "light perception" (LP), and "no light perception." More quantitative measures would be desirable, especially for clinical studies. The results of clinical VA measurements, Early Treatment Diabetic Retinopathy Study (ETDRS) charts, and the Freiburg Visual Acuity Test (FrACT) were compared. The FrACT is a computerized visual acuity test that can present very large Landolt C optotypes when necessary. METHODS: Examined were 100 eyes of 100 patients with various eye diseases (e.g., diabetic retinopathy, ARMD), covering a range of VAs from LP to decimal 0.32. The FrACT optotypes were presented on a 17-inch LCD monitor with random orientation. After extensive training, two ETDRS and FrACT measurements were obtained. The testing distance was 50 or 100 cm. RESULTS: ETDRS and FrACT coincided closely for VA > or = 0.02 (n = 80). ETDRS measures were successfully obtainable down to CF (at 30 cm; test-retest averaged over all patients, coefficient of variation [CV](ETDRS) = 9% +/- 8%), and FrACT provided reproducible measurements down to HM (test-retest CV(FrACT) =12% +/- 11%). For CF (n = 6), both ETDRS and FrACT resulted in a mean VA of 0.014 +/- 0.003 (range, 0.01-0.02). The VA results of FrACT for HM (n = 12) were 0.005 +/- 0.002 (range, 0.003-0.009); the individual values were highly reproducible. No results were obtainable for LP (n = 2). CONCLUSIONS: The three acuity procedures concur above a VA of 0.02. The results suggest that the category CF at 30 cm can be replaced by 0.014, using ETDRS or FrACT. Using FrACT, one can even reproducibly quantify VA in the HM-range, yielding a mean VA of 0.005.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.05-0981

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 994

Metadata

Authors
Schulze-Bonsel, K., Feltgen, N., Burau, H., Hansen, L., & Bach, M.
Venue
Investigative Opthalmology & Visual Science
Published
2006-03-01
Volume
47
Issue
3
Pages
1236
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1980404110
Cited by
994
References
1
FWCI
7.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Visual Acuities “Hand Motion” and “Counting Fingers” Can Be Quantified with the Freiburg Visual Acuity Test. https://app.cochat.ai/papers/10.1167/iovs.05-0981
The paper
Schulze-Bonsel, K., Feltgen, N., Burau, H., Hansen, L., & Bach, M. (2006). Visual Acuities “Hand Motion” and “Counting Fingers” Can Be Quantified with the Freiburg Visual Acuity Test. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.05-0981

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.