CoChat

Measuring Rod and Cone Dynamics in Age-Related Maculopathy

Open access
Dimitrov, Peter N., Guymer, Robyn H., Zele, Andrew J., Anderson, Andrew J., Vingrys, Algis J. · 2008 · Investigative Opthalmology & Visual Science
Cited by 109

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: A cathode-ray-tube (CRT) monitor-based technique was used to isolate clinically significant components of dark adaptation. The utility of the technique in identifying adaptation abnormalities in eyes with age-related maculopathy (ARM) is described. METHODS: A CRT dark adaptometer was developed to assess cone and rod recovery after photopigment bleach. The following measures were obtained: cone recovery rate (R(c); in decades per minute) and absolute threshold (Tf(c); log candelas per square meter), rod recovery rate (R(r); decades per minute), and rod-cone transition (rod-cone break [RCB], in minutes). These components were isolated by appropriately selecting stimulus size, stimulus location, pigment bleach, and test duration and by coupling the CRT with judiciously selected neutral-density (ND) filters. The protocol was developed by using 5 young observers and was tested on 27 subjects with ARM in the study eye and 22 age-matched control subjects. RESULTS: The parameters necessary for effective isolation of cone and early phase rod dark adaptation were a 2.6 ND filter (for a standard CRT monitor, 0.08-80 cd . m(-2) luminance output); a 4 degrees foveated, 200-ms, achromatic spot; approximately 30% pigment bleaching; and a 30-minute test duration. These settings returned obvious rod and cone recovery curves in control and ARM eyes that were compatible with conventional test methods and identified 93% of participants with ARM as having delayed dynamics in at least one of the parameters. Cone recovery dynamics were significantly slower in the ARM group when compared with age-matched control subjects (R(c), 0.99 +/- 0.35 vs. 2.63 +/- 0.61 decades . min(-1), P < 0.0001). Three of the 27 eyes with ARM did not achieve RCB during the allowed duration (30 minutes). The remaining eyes with ARM (n = 24) exhibited a significant delay in rod recovery (R(r)(,) ARM, 0.16 +/- 0.03 vs. controls, 0.22 +/- 0.02 decades . min(-1), P < 0.0001) and the average time to RCB (+/-SD) in the ARM group was significantly longer than in the control subjects (19.12 +/- 5.17 minutes vs. 10.40 +/- 2.49 minutes, P < 0.0001). CONCLUSIONS: The CRT dark-adaptation technique described in this article is an effective test for identifying abnormalities in cone and rod recovery. Slowed cone and rod recovery and a delayed RCB were evident in the eyes with ARM. The test method is potentially useful for clinical intervention trials in which ARM progression is monitored.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.06-1048

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 109

Metadata

Authors
Dimitrov, P. N., Guymer, R. H., Zele, A. J., Anderson, A. J., & Vingrys, A. J.
Venue
Investigative Opthalmology & Visual Science
Published
2008-01-01
Volume
49
Issue
1
Pages
55
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1577413770
Cited by
109
References
3
FWCI
5.02
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.