The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
High-Resolution Imaging with Adaptive Optics in Patients with Inherited Retinal Degeneration
Abstract
PURPOSE: To investigate macular photoreceptor structure in patients with inherited retinal degeneration using high-resolution images and to correlate the findings with clinical phenotypes and genetic mutations. METHODS: Adaptive optics scanning laser ophthalmoscopy (AOSLO) images of photoreceptors were obtained in 16 eyes: five with retinitis pigmentosa (RP), three with cone-rod dystrophy (CRD), and eight without retinal disease. A quadratic model was used to illustrate cone spacing as a function of retinal eccentricity. Cone spacing at 1 degrees eccentricity was compared with standard measures of central visual function, including best-corrected visual acuity (BCVA), foveal threshold, and multifocal electroretinogram (mfERG) amplitude and timing. Intervisit variations were studied in one patient with RP and one patient with CRD. Screening of candidate disease genes identified mutations in two patients, one with RP (a rhodopsin mutation) and the other with CRD (a novel RPGR-ORF15 mutation). RESULTS: Cone spacing values were significantly different from normal for patients with RP (P = 0.01) and CRD (P < 0.0001) and demonstrated a statistically significant correlation with foveal threshold (P = 0.0003), BCVA (P = 0.01), and mfERG amplitude (P = 0.008). Although many RP patients showed normal cone spacing within 1 degrees of fixation, cones could not be unambiguously identified in several retinal regions. Cone spacing increased in all CRD patients, even those with early disease. Little variation was observed in cone spacing measured during two sessions fewer than 8 days apart. CONCLUSIONS: AOSLO images can be used to study macular cones with high resolution in patients with retinal degeneration. The authors present the first report of cone structure in vivo in patients with mutations in rhodopsin and RPGR-ORF15 and show that macular cones display distinct characteristics, depending on the underlying disease. AOSLO imaging, therefore, can provide new insight into possible mechanisms of cone vision loss in patients with retinal degeneration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 2,790
Supernormal vision and high-resolution retinal imaging through adaptive optics
Liang, J., Williams, D. R., & Miller, D. T. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002884 · Cited by 1,454
The arrangement of the three cone classes in the living human eye
Roorda, A., & Williams, D. R. (1999) · Nature · doi:10.1038/17383 · Cited by 982
Self-citationAdaptive optics scanning laser ophthalmoscopy
Roorda, A., Romero-Borja, F., Donnelly III, W. J., Queener, H., Hebert, T. J., & Campbell, M. C. W. (2002) · Optics Express · doi:10.1364/oe.10.000405 · Cited by 967
Self-citationStandard for clinical electroretinography
Marmor, M. F., Arden, G. B., Nilsson, S.-E., Zrenner, E., & International Standardization Committee (1989) · Documenta Ophthalmologica · doi:10.1007/bf00154486 · Cited by 806
Aberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Three-dimensional Retinal Imaging with High-Speed Ultrahigh-Resolution Optical Coherence Tomography
Wojtkowski, M., Srinivasan, V., Fujimoto, J. G., Ko, T., Schuman, J. S., Kowalczyk, A., & Duker, J. S. (2005) · Ophthalmology · doi:10.1016/j.ophtha.2005.05.023 · Cited by 640
Confocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
Standard for clinical electroretinography (2004 update)
Marmor, M. F., Holder, G. E., Seeliger, M. W., & Yamamoto, S. (2004) · Documenta Ophthalmologica · doi:10.1023/b:doop.0000036793.44912.45 · Cited by 505
Identification and characterization of rod-derived cone viability factor
Léveillard, T., Mohand-Saïd, S., Lorentz, O., Hicks, D., Fintz, A.-C., Clérin, E., Simonutti, M., Forster, V., Cavusoglu, N., Chalmel, F., et al. (2004) · Nature Genetics · doi:10.1038/ng1386 · Cited by 438
Cited by
Cehajic-Kapetanovic, J., Xue, K., Martinez-Fernandez de la Camara, C., Nanda, A., Davies, A., Wood, L. J., Salvetti, A. P., Fischer, M. D., Aylward, J. W., Barnard, A. R., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0763-1 · Cited by 368
Metadata
- Authors
- Duncan, J. L., Zhang, Y., Gandhi, J., Nakanishi, C., Othman, M., Branham, K. E. H., Swaroop, A., & Roorda, A.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2007-07-01
- Volume
- 48
- Issue
- 7
- Pages
- 3283
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2044404404
- Cited by
- 262
- References
- 44
- FWCI
- 3.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-Resolution Imaging with Adaptive Optics in Patients with Inherited Retinal Degeneration. https://app.cochat.ai/papers/10.1167/iovs.06-1422
- The paper
- Duncan, J. L., Zhang, Y., Gandhi, J., Nakanishi, C., Othman, M., Branham, K. E. H., Swaroop, A., & Roorda, A. (2007). High-Resolution Imaging with Adaptive Optics in Patients with Inherited Retinal Degeneration. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.06-1422
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.