Temporal Properties of Compensation for Positive and Negative Spectacle Lenses in Chicks
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: Chicks' eyes rapidly compensate for defocus imposed by spectacle lenses by changing their rate of elongation and their choroidal thickness. Compensation may involve internal emmetropization signals that rise and become saturated during episodes of lens wear and decline between episodes. The time constants of these signals were measured indirectly by measuring the magnitude of lens compensation in refractive error and ocular dimensions as a function of the duration of episodes and the intervals between the episodes. METHODS: First, in a study of how quickly the signals rose, chicks were subjected to episodes of lens-wear of various durations (darkness otherwise), and the duration required to cause a half-maximum effect (rise-time) was estimated. Second, in a study of how quickly the signals declined, various dark intervals were imposed between episodes of lens-wear, and the interval required to reduce the maximum effect by half (fall-time) was estimated. RESULTS: The rise-times for the rate of ocular elongation and choroidal thickness were approximately 3 minutes for positive and negative lenses. The fall-times had a broad range of time courses: Positive lenses caused an enduring inhibition of ocular elongation with a fall-time of 24 hours. In contrast, negative lenses caused a transient stimulation of ocular elongation with a fall-time of 0.4 hour. CONCLUSIONS: The effects of episodes of defocus rise rapidly with episode duration to an asymptote and decline between episodes, with the time course depending strongly on the sign of defocus and the ocular component. The complex etiology of human myopia may reflect these temporal properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In a Matter of Minutes, the Eye Can Know Which Way to Grow
Zhu, X., Park, T. W., Winawer, J., & Wallman, J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0956 · Cited by 179
Self-citationCone signals for spectacle-lens compensation: Differential responses to short and long wavelengths
Rucker, F. J., & Wallman, J. (2008) · Vision Research · doi:10.1016/j.visres.2008.06.003 · Cited by 99 · cited 1×
“A colleague has discovered the same phenomenon in eyes compensating for lenses under dim illumination.(40) We speculate that this may be a reflection of a process that normally drives the two eyes toward a common refraction (i.”
Self-citation
Cited by
Nickla, D. L., & Wallman, J. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2009.12.002 · Cited by 1,945
Self-citationIMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
“It has been argued that these nonlinearities come about because the compensating signals produced by defocus have relatively rapid rise times to saturation levels and that these signals decay more slowly between exposures.(181,302,311) In a detailed study of the rise and fall times for individual exposures, Zhu and Wa…”
BackgroundIMI Prevention of Myopia and Its Progression
Jonas, J. B., Ang, M., Cho, P., Guggenheim, J. A., He, M. G., Jong, M., Logan, N. S., Liu, M., Morgan, I., Ohno-Matsui, K., et al. (2021) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.62.5.6 · Cited by 475
Self-citationTime outdoors and the prevention of myopia
French, A. N., Ashby, R. S., Morgan, I. G., & Rose, K. A. (2013) · Experimental Eye Research · doi:10.1016/j.exer.2013.04.018 · Cited by 395
Lam, C. S. Y., Tang, W. C., Tse, D. Y.-Y., Tang, Y. Y., & To, C. H. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-303914 · Cited by 368
Metadata
- Authors
- Zhu, X., & Wallman, J.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2009-01-01
- Volume
- 50
- Issue
- 1
- Pages
- 37
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2005567824
- Cited by
- 86
- References
- 2
- FWCI
- 2.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.