The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Individual Variations in Human Cone Photoreceptor Packing Density: Variations with Refractive Error
Open accessAbstract
PURPOSE: To measure the variation in human cone photoreceptor packing density across the retina, both within an individual and between individuals with different refractive errors. METHODS: A high-resolution adaptive optics scanning laser ophthalmoscope was used to image the cones of 11 human eyes. Five subjects with emmetropia and six subjects with myopia were tested (+0.50 to -7.50 D). For each subject, four approximately 10 degrees x 1.5 degrees strips of cone images were obtained. Each strip started at the fovea and proceeded toward the periphery along the four primary meridians. The position of each cone within the sampling windows was digitized manually by the investigator. From these cone counts, the density of the cones was calculated for a set of fixed distances from the fovea at locations throughout the image. RESULTS: Cone photoreceptor packing density decreased from 27,712 cells/mm(2) to 7,070 cells/mm(2) from a retinal eccentricity of 0.30 to 3.40 mm along the superior meridian in five emmetropic eyes. Cone photoreceptor packing density (cells per square millimeter) was significantly lower in myopic eyes than in emmetropic eyes. At a given location, there was considerable individual variation in cone photoreceptor packing density, although more than 20% of the variance could be accounted for by differences in axial length. CONCLUSIONS: The results provide a baseline analysis of individual difference in cone photoreceptor packing density in healthy human eyes. As predicted by retinal stretching models, cone photoreceptor packing density is lower in highly myopic eyes than in emmetropic eyes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoreceptor degeneration and dysfunction in aging and age-related maculopathy
Jackson, G. R., Owsley, C., & Curcio, C. A. (2002) · Ageing Research Reviews · doi:10.1016/s1568-1637(02)00007-7 · Cited by 317
Cited by
Enhanced Depth Imaging Optical Coherence Tomography of the Choroid in Highly Myopic Eyes
Fujiwara, T., Imamura, Y., Margolis, R., Slakter, J. S., & Spaide, R. F. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2009.04.029 · Cited by 823
Optical coherence tomography: Imaging of the choroid and beyond
Mrejen, S., & Spaide, R. F. (2013) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2012.12.001 · Cited by 477
Adaptation of the central retina for high acuity vision: Cones, the fovea and the avascular zone
Provis, J. M., Dubis, A. M., Maddess, T., & Carroll, J. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2013.01.005 · Cited by 298
Variation of Cone Photoreceptor Packing Density with Retinal Eccentricity and Age
Song, H., Chui, T. Y. P., Zhong, Z., Elsner, A. E., & Burns, S. A. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-7199 · Cited by 267
Self-citationAdaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
Self-citation
Metadata
- Authors
- Chui, T. Y. P., Song, H., & Burns, S. A.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2008-10-01
- Volume
- 49
- Issue
- 10
- Pages
- 4679
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2020609536
- Cited by
- 191
- References
- 1
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Individual Variations in Human Cone Photoreceptor Packing Density: Variations with Refractive Error. https://app.cochat.ai/papers/10.1167/iovs.08-2135
- The paper
- Chui, T. Y. P., Song, H., & Burns, S. A. (2008). Individual Variations in Human Cone Photoreceptor Packing Density: Variations with Refractive Error. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.08-2135
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.