CoChat

SPARC-null Mice Exhibit Lower Intraocular Pressures

Haddadin, Ramez I., Oh, Dong-Jin, Kang, Min Hyung, Filippopoulos, Theodoros, Gupta, Meenakashi, Hart, Lois, Sage, E. Helene, Rhee, Douglas J. · 2009 · Investigative Opthalmology & Visual Science

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Abstract

PURPOSE: SPARC is a matricellular protein that is highly expressed in remodeling tissues, including the trabecular meshwork and ciliary body. The hypothesis for the study was that SPARC contributes to the regulation of intraocular pressure (IOP). The IOPs of SPARC-null mice, their corresponding wild-type (WT), and heterozygous animals were compared. METHODS: Diurnal and nocturnal IOPs of C57Bl/6x129SvJ WT, SPARC-null, and heterozygous mice were measured. Fluorophotometric measurements were made to assess aqueous turnover. Central corneal thickness (CCT) was measured using histology, ultrasound biomicroscopy, and optical coherence tomography. Iridocorneal angles were examined using light microscopy (LM). RESULTS: During the day, the mean IOP of SPARC-null mice (n = 142, 16.9 +/- 2.4 mm Hg) was lower than that of both WT mice (n = 104, 19.9 +/- 2.9 mm Hg; P < 10(-12)), and heterozygotes (n = 38, 19.3 +/- 2.5 mm Hg; P < 10(-4)). At night, SPARC-null mice also exhibited a blunted increase in IOP in comparison to WT and heterozygous mice. CCTs were not significantly different between WT and SPARC-null mice. Heterozygous mice tended to have thicker corneas (3.4%). Fluorophotometric measurements suggest that aqueous turnover rates in SPARC-null mice are equal to if not greater than rates in WT mice. LM of the SPARC-null iridocorneal angle revealed morphology that is indistinguishable from WT. CONCLUSIONS: SPARC-null mice have lower IOPs than do their WT counterparts with equal CCTs. The rate of aqueous turnover suggests that the mechanism is enhanced outflow resistance.

Overview

Integrity signals

Registry

Crossref · 10.1167/iovs.08-2489

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 54 references

Cited by

See all 71

Metadata

Authors
Haddadin, R. I., Oh, D.-J., Kang, M. H., Filippopoulos, T., Gupta, M., Hart, L., Sage, E. H., & Rhee, D. J.
Affiliations
  • Massachusetts Eye and Ear Infirmary (US)
  • Benaroya Research Institute (US)
Venue
Investigative Opthalmology & Visual Science
Published
2009-08-01
Volume
50
Issue
8
Pages
3771
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2154381096
Cited by
71
References
53
Citations by year
2026: 1 · 2024: 3 · 2023: 3 · 2022: 3 · 2021: 4 · 2020: 2 · 2019: 3 · 2018: 1 · 2017: 4 · 2016: 6 · 2015: 7 · 2014: 10 · 2013: 8 · 2012: 4
FWCI
5.42
Type
journal article
Language
en
Open access
closed
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Scheme for Promotion of Academic and Research Collaboration
  • National Eye Institute (EY014104, P30EY014104)
Topics
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
  • Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
Keywords
SPARC, intraocular pressure, SPARC-null mice, trabecular meshwork, ciliary body, aqueous humor outflow resistance, central corneal thickness, anterior chamber angle, diurnal IOP variation, glaucoma
MeSH terms
Animals, Anterior Eye Segment, Aqueous Humor, Circadian Rhythm, Cornea, Female, Intraocular Pressure, Male, Mice, Inbred C57BL, Tonometry, Ocular, Fluorophotometry, Osteonectin, Gene Deletion, Mice, Knockout, Microscopy, Acoustic, Tomography, Optical Coherence, Mice

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.