CoChat

Peripheral Retinal Drusen and Reticular Pigment: Association with CFHY402H and CFHrs1410996 Genotypes in Family and Twin Studies

Open access
Seddon, Johanna M., Reynolds, Robyn, Rosner, Bernard · 2009 · Investigative Opthalmology & Visual Science
Cited by 66

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

PURPOSE: To evaluate the relationship between peripheral retinal drusen and reticular pigment changes and genotypes associated with age-related macular degeneration (AMD). METHODS: Using standard protocols, 2103 family members and twins were examined. Clinical and photographic data were graded according to the Clinical Age-Related Maculopathy Grading System (CARMS) as grade 1 (no AMD), grade 2 (small drusen and/or pigment irregularities), grade 3 (intermediate AMD), grade 4 (central or noncentral geographic atrophy), or grade 5 (neovascular disease). Peripheral drusen and reticular pigment were assessed with a standardized examination. Associations between six AMD genetic variants and retinal phenotypes were analyzed. RESULTS: AMD grade was associated with peripheral drusen and reticular pigment (odds ratio [OR] 1.9 for advanced AMD; P<0.001). Both peripheral retinal phenotypes were associated with AMD related genotypes. For CFHY402H, the OR was 2.8 for the CC genotype versus TT (P for trend<0.001, with increase in peripheral drusen with each additional risk [C] allele). Similar results were seen for CFHrs1410996. Reticular pigment was related to CFHY402H, with OR 2.0 for the CC genotype versus TT (P for trend<0.001, for increase in pigment with each risk allele) and to CFHrs1410996 (P for trend=0.006). These findings were not seen for the LOC387715 A69S gene region, CFB, C2, or C3. Among individuals with no or minimal maculopathy, CFH variants were associated with more than a twofold increased risk of drusen and reticular pigment. CONCLUSIONS: Peripheral retinal drusen and reticular pigment are associated with AMD and with CFHY402H and CFHrs1410996 genotypes, adjusting for AMD grade. These phenotypes may be a marker of genetic susceptibility for patients with or without AMD.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.08-2514

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Seddon, J. M., Reynolds, R., & Rosner, B.
Venue
Investigative Opthalmology & Visual Science
Published
2009-02-01
Volume
50
Issue
2
Pages
586
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1975623665
Cited by
66
References
9
FWCI
6.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.