Cited by 25Corneal surgery and disordersCorneal Surgery and TreatmentsCollagen: Extraction and Characterization

Collagen Fibril Orientation and Corneal Curvature

Open access
Fullwood, Nigel J.·2004·Structure

Integrity signals

Registry

Crossref · 10.1016/j.str.2004.01.019

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Maurice and colleagues initially employed X-rays to investigate collagen fiber arrangement in corneal tissues, enabling quantification of orientation and content across the cornea and limbus, with changes detected via X-ray scattering patterns.

    “Maurice and colleagues initially employed X‐rays to investigate structural features pertaining to the arrangement of collagen fibers in corneal tissues, enabling the quantification of the orientation and content of collagen fibers across the cornea and limbus, with changes in fiber arrangement being readily detected via X‐ray scattering patterns.[ 94 , 105 , 111 ]”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Fullwood, N. J.
Affiliations
Lancaster University (GB)
Corresponding author
Fullwood, Nigel J.
Venue
Structure
Publisher
Elsevier BV
Published
2004-02
Volume
12
Issue
2
Pages
169-170
ISSN
0969-2126 (ISSN-L)
OpenAlex
W2023338373
Cited by
25
References
9
Citations by year
2026: 2 · 2025: 1 · 2024: 2 · 2023: 1 · 2022: 3 · 2021: 1 · 2020: 1 · 2019: 2 · 2018: 1 · 2017: 2 · 2015: 3 · 2014: 1 · 2013: 2 · 2012: 1
FWCI
0.00
Type
journal article
Language
en
Open access
Locations
  • Structure (publishedVersion)
  • PubMed (publishedVersion)
  • Lancaster EPrints (Lancaster University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
  • Physical Sciences › Materials Science › Biomaterials › Collagen: Extraction and Characterization
Keywords
collagen fibril orientation, cornea, corneal curvature, corneal biomechanics
MeSH terms
Animals, Corneal Stroma, Humans, Sclera, X-Ray Diffraction, Limbus Corneae, Fibrillar Collagens

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review