Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 389

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

The Microbead Occlusion Model: A Paradigm for Induced Ocular Hypertension in Rats and Mice

Open access
Sappington, Rebecca M., Carlson, Brian J., Crish, Samuel D., Calkins, David J. · 2010 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: Elevated intraocular pressure (IOP) is an important risk factor for glaucoma. Animal models often involve techniques for IOP elevation that are surgically invasive. Here the authors describe a novel and relatively simple method for inducing a highly consistent, modest, and repeatable elevation in IOP for rats and mice. METHODS: IOP was elevated unilaterally by injection of polystyrene microbeads into the anterior chamber to occlude aqueous outflow in rats (2.5-7 microL) and mice (1 microL). The fellow eye received an equivalent saline injection as internal control. The authors used tonometry to measure microbead-induced IOP elevations. Optic nerves were processed histologically to determine axon loss. RESULTS: For rats, a single injection of microbeads raised IOP by 21% to 34%, depending on volume, for approximately 2 weeks, though they were not tracked to full recovery. IOP in the saline-injected eye was constant. An additional injection (5 microL) extended the elevation to 8 weeks. Cumulative pressure exposure for both injections increased linearly. For mice, a single 1-microL injection of microbeads elicited a highly regular 30% elevation in IOP that persisted for more than 3 weeks, with a linear rise in cumulative pressure exposure. For both rats and mice, interanimal variability on a given day was modest, approximately 5% of the mean IOP measurement. Extended elevations (4-5 weeks) induced approximately a 20% loss of axons in both rats and mice. CONCLUSIONS: These data support a novel and flexible model of modest ocular hypertension with axon loss. The maximal duration of IOP elevation will be further characterized in future studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.09-3947

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 389

Metadata

Authors
Sappington, R. M., Carlson, B. J., Crish, S. D., & Calkins, D. J.
Venue
Investigative Opthalmology & Visual Science
Published
2010-01-01
Volume
51
Issue
1
Pages
207
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2078684091
Cited by
389
References
23
FWCI
19.78
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.