Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 590

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Pharmacokinetics and Pharmacodynamics of a Sustained-Release Dexamethasone Intravitreal Implant

Chang-Lin, Joan-En, Attar, Mayssa, Acheampong, Andrew A., Robinson, Michael R., Whitcup, Scott M., Kuppermann, Baruch D., Welty, Devin·2011·Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To determine the pharmacokinetics and pharmacodynamics of a sustained-release dexamethasone (DEX) intravitreal implant (Ozurdex; Allergan, Inc.). METHODS: Thirty-four male monkeys (Macaca fascicularis) received bilateral 0.7-mg DEX implants. Blood, vitreous humor, and retina samples were collected at predetermined intervals up to 270 days after administration. DEX was quantified by liquid chromatography-tandem mass spectrometry, and cytochrome P450 3A8 (CYP3A8) gene expression was analyzed by real-time reverse transcription-polymerase chain reaction. RESULTS: DEX was detected in the retina and vitreous humor for 6 months, with peak concentrations during the first 2 months. After 6 months, DEX was below the limit of quantitation. The C(max) (T(max)) and AUC for the retina were 1110 ng/g (day 60) and 47,200 ng · d/g, and for the vitreous humor were 213 ng/mL (day 60) and 11,300 ng · d/mL, respectively. The C(max) (T(max)) of DEX in plasma was 1.11 ng/mL (day 60). Compared with the level in the control eyes (no DEX implant), CYP3A8 expression in the retina was upregulated threefold up to 6 months after injection of the implant (0.969 ± 0.0565 vs. 3.07 ± 0.438; P < 0.05 up to 2-month samples). CONCLUSIONS: The in vivo release profile of the DEX implant in an animal eye was similar to the pharmacokinetics achieved with pulse administration of corticosteroids (high initial drug concentration, followed by a prolonged period of low concentration). These results are consistent with those in clinical studies supporting the use of the DEX implant for the extended management of posterior segment diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-5285

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 590

Metadata

Authors
Chang-Lin, J.-E., Attar, M., Acheampong, A. A., Robinson, M. R., Whitcup, S. M., Kuppermann, B. D., & Welty, D.
Venue
Investigative Opthalmology & Visual Science
Published
2011-01-05
Volume
52
Issue
1
Pages
80
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2058913110
Cited by
590
References
2
FWCI
13.98
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.