Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 221

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Human Optical Axial Length and Defocus

Open access
Read, Scott A., Collins, Michael J., Sander, Beata P. · 2010 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To investigate the short-term influence of imposed monocular defocus on human optical axial length (the distance from anterior cornea to retinal pigment epithelium) and ocular biometrics. METHODS: Twenty-eight young adult subjects (14 myopes, 14 emmetropes) had eye biometrics measured before and 30 and 60 minutes after exposure to monocular (right eye) defocus. Four different monocular defocus conditions were tested, each on a separate day: control (no defocus), myopic (+3 D defocus), hyperopic (-3 D defocus), and diffuse (0.2 density Bangerter filter) defocus. The fellow eye was optimally corrected (no defocus). RESULTS: Imposed defocus caused small but significant changes in optical axial length (P < 0.0001). A significant increase in optical axial length (mean change, +8 ± 14 μm; P = 0.03) occurred after hyperopic defocus, and a significant reduction in optical axial length (mean change, -13 ± 14 μm; P = 0.0001) was found after myopic defocus. A small increase in optical axial length was observed after diffuse defocus (mean change, +6 ± 13 μm; P = 0.053). Choroidal thickness also exhibited some significant changes with certain defocus conditions. No significant difference was found between myopes and emmetropes in the changes in optical axial length or choroidal thickness with defocus. CONCLUSIONS: Significant changes in optical axial length occurred in human subjects after 60 minutes of monocular defocus. The bidirectional optical axial length changes observed in response to defocus implied the human visual system is capable of detecting the presence and sign of defocus and altering optical axial length to move the retina toward the image plane.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.10-5457

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 221

Metadata

Authors
Read, S. A., Collins, M. J., & Sander, B. P.
Venue
Investigative Opthalmology & Visual Science
Published
2010-12-01
Volume
51
Issue
12
Pages
6262
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2042874125
Cited by
221
References
1
FWCI
6.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human Optical Axial Length and Defocus. https://app.cochat.ai/papers/10.1167/iovs.10-5457
The paper
Read, S. A., Collins, M. J., & Sander, B. P. (2010). Human Optical Axial Length and Defocus. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.10-5457

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.