The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
The Effect of Two-Zone Concentric Bifocal Spectacle Lenses on Refractive Error Development and Eye Growth in Young Chicks
Open accessAbstract
PURPOSE: To characterize the effects on refractive error development and eye growth in young chicks of two-zone concentric lens designs, which differentially affect the defocus experiences of central and peripheral retinal regions. METHODS: Monocular defocusing lenses were worn for 5 days from 17 days of age. Four two-zone concentric lens designs (overall optical zone diameter, 10 mm) combining plano with either -5- or +5-D power were used. Lens designs were as follows: (1) +5 D center (+5C), (2) +5 D periphery (+5P), (3) -5 D center (-5C), and (4) -5 D peripheral (-5P), with plano in periphery for all C-designs and in the center for P-designs. Five central zone diameters (CZDs) were tested, ranging from 2.5 to 6.5 mm in 1-mm increments. Plano, +5- and -5-D single-vision (SV) lenses were used as the control. A minimum of six birds were included in each lens group. RESULTS: For the two-zone lenses, the P designs (i.e., peripheral defocus) had greater effects than the C designs (i.e., central defocus) on both on-axis eye growth and refractions. All but the 6.5-mm CZD +5P lens induced larger changes than the +5SV lens. The +5C lenses with CZD less than 5.5 mm had little effect. The two-zone -5-D lenses had less effect than the -5SV lens, and only the 6.5-mm CZD lens of the -5C series had a significant effect. CONCLUSIONS: The results demonstrate that peripheral defocus can influence both peripheral and central refractive development. The inhibitory effect on axial eye growth of the +5P lenses opens the possibility that appropriately designed concentric lenses may control the progression of human myopia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In a Matter of Minutes, the Eye Can Know Which Way to Grow
Zhu, X., Park, T. W., Winawer, J., & Wallman, J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0956 · Cited by 179
Cited by
Morgan, I. G., Ohno-Matsui, K., & Saw, S.-M. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60272-4 · Cited by 1,871
A 3‐year Randomized Clinical Trial of MiSight Lenses for Myopia Control
Chamberlain, P., Peixoto‐de‐Matos, S. C., Logan, N. S., Ngo, C., Jones, D., & Young, G. (2019) · Optometry and Vision Science · doi:10.1097/opx.0000000000001410 · Cited by 516
IMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
IMI Prevention of Myopia and Its Progression
Jonas, J. B., Ang, M., Cho, P., Guggenheim, J. A., He, M. G., Jong, M., Logan, N. S., Liu, M., Morgan, I., Ohno-Matsui, K., et al. (2021) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.62.5.6 · Cited by 475
Self-citationScleral structure and biomechanics
Boote, C., Sigal, I. A., Grytz, R., Hua, Y., Nguyen, T. D., & Girard, M. J. A. (2020) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.100773 · Cited by 387
Metadata
- Authors
- Liu, Y., & Wildsoet, C.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-02-22
- Volume
- 52
- Issue
- 2
- Pages
- 1078
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W1982714409
- Cited by
- 171
- References
- 1
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.