The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Shadow Removal and Contrast Enhancement in Optical Coherence Tomography Images of the Human Optic Nerve Head
Abstract
PURPOSE: To improve the quality of optical coherence tomography (OCT) images of the optic nerve head (ONH). METHODS: Two algorithms were developed, one to compensate for light attenuation and the other to enhance contrast in OCT images. The former was borrowed from developments in ultrasound imaging and was proven suitable with either time- or spectral-domain OCT. The latter was based on direct application of pixel intensity exponentiation. The performances of these two algorithms were tested on spectral-domain OCT images of four adult ONHs. RESULTS: Application of the compensation algorithm significantly reduced the intralayer contrast (from 0.74 ± 0.16 to 0.17 ± 0.12; P < 0.001), indicating successful blood vessel shadow removal. Furthermore, compensation dramatically improved the visibility of deeper ONH tissues, such as the peripapillary sclera and lamina cribrosa. Application of the contrast-enhancement algorithm significantly increased the interlayer contrast (from 0.48 ± 0.22 to a maximum of 0.89 ± 0.05; P < 0.001) and thus allowed a better differentiation of tissue boundaries. Contrast enhancement was robust only when compensation was considered. CONCLUSIONS: The proposed algorithms are simple and can significantly improve the quality of ONH images clinically captured with OCT. This study has important implications, as it will help improve our ability to perform automated segmentation of the ONH; quantify the morphometry and biomechanics of ONH tissues in vivo; and identify potential risk indicators for glaucoma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light Scattering by Small Particles
van de Hulst, H. C. (1981) · CERN Document Server (European Organization for Nuclear Research) · Cited by 7,938
(1999) · Sensor Review · doi:10.1108/sr.1999.08719bae.001 · Cited by 6,021
Global data on visual impairment in the year 2002.
(2004) · Europe PMC (PubMed Central) · Cited by 4,157
Enhanced Depth Imaging Spectral-Domain Optical Coherence Tomography
Spaide, R. F., Koizumi, H., & Pozonni, M. C. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.05.032 · Cited by 2,180
Optic Nerve Damage in Human Glaucoma: II. The Site of Injury and Susceptibility to Damage
Quigley, H. A. (1981) · Archives of Ophthalmology · doi:10.1001/archopht.1981.03930010635009 · Cited by 1,244
Burgoyne, C. F., Crawford Downs, J., Bellezza, A. J., Francis Suh, J.-K., & Hart, R. T. (2005) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2004.06.001 · Cited by 1,140
Hartmann, M. (1984) · Acta Polymerica · doi:10.1002/actp.1984.010350426 · Cited by 1,071
IMAMURA, Y., FUJIWARA, T., MARGOLIS, R., & SPAIDE, R. F. (2009) · Retina · doi:10.1097/iae.0b013e3181be0a83 · Cited by 955
Handbook of Optical Coherence Tomography
(2001) · CRC Press eBooks · doi:10.1201/b14024 · Cited by 580
Biomechanics of the optic nerve head
Sigal, I. A., & Ethier, C. R. (2009) · Experimental Eye Research · doi:10.1016/j.exer.2009.02.003 · Cited by 331
Self-citation
Cited by
Vermeer, K. A., Mo, J., Weda, J. J. A., Lemij, H. G., & de Boer, J. F. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000322 · Cited by 373
Structured layer surface segmentation for retina OCT using fully convolutional regression networks
He, Y., Carass, A., Liu, Y., Jedynak, B. M., Solomon, S. D., Saidha, S., Calabresi, P. A., & Prince, J. L. (2021) · Medical Image Analysis · doi:10.1016/j.media.2020.101856 · Cited by 104
Patel, N., Pass, A., Mason, S., Gibson, C. R., & Otto, C. (2018) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2017.6226 · Cited by 92
Selective Search and Sequential Detection for Standard Plane Localization in Ultrasound
Ni, D., Li, T., Yang, X., Qin, J., Li, S., Chin, C.-T., Ouyang, S., Wang, T., & Chen, S. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-41083-3_23 · Cited by 33
Metadata
- Authors
- Girard, M. J. A., Strouthidis, N. G., Ethier, C. R., & Mari, J. M.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2011-09-28
- Volume
- 52
- Issue
- 10
- Pages
- 7738
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2121357494
- Cited by
- 278
- References
- 26
- FWCI
- 7.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Shadow Removal and Contrast Enhancement in Optical Coherence Tomography Images of the Human Optic Nerve Head. https://app.cochat.ai/papers/10.1167/iovs.10-6925
- The paper
- Girard, M. J. A., Strouthidis, N. G., Ethier, C. R., & Mari, J. M. (2011). Shadow Removal and Contrast Enhancement in Optical Coherence Tomography Images of the Human Optic Nerve Head. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.10-6925
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.