CoChat

Effect and Distribution of Contrast Medium after Injection into the Anterior Suprachoroidal Space in Ex Vivo Eyes

Open access
Seiler, Gabriela S., Salmon, Jacklyn H., Mantuo, Rebecca, Feingold, Steven, Dayton, Paul A., Gilger, Brian C. · 2011 · Investigative Opthalmology & Visual Science
Cited by 39

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: To determine the effects and posterior distribution of injections made into the anterior suprachoroidal space (SCS). METHODS: The anterior SCS of adult porcine and canine ex vivo eyes was cannulated. Latex injections and high frequency ultrasound (50 MHz) was used to image the effect and distension of the SCS. Flow characteristics and percentage maximal distribution of microbubble contrast injection into the SCS were assessed by 2D and 3D ultrasound. RESULTS: Mean (SD) distension of the SCS with PBS increased from 1.57 (0.48) mm after injection of 250 μL to 3.28 (0.57) mm with 1000 μL PBS. Eyes injected at physiologic IOP had no significant difference in SCS distension. In real-time 2D ultrasound, the contrast agent flowed from the injection site to the opposite ventral anterior SCS and the posterior SCS. Contrast arrived at the opposite and posterior SCS 7.8 (4.6) and 7.7 (4.6) seconds after injection, respectively. In sagittal images, contrast was visible in 24.0%to 27.2% of the SCS; in 10 of 12 eyes, contrast reached the posterior pole of the eye. In 3D images, contrast medium occupied 39.0% to 52.1% of the entire SCS. CONCLUSIONS: These results suggest that the SCS can expand, in a dose-dependent manner, to accommodate various volumes of fluid and that it is possible to image the SCS with ultrasound contrast. The authors' hypothesis that a single anterior SCS injection can reach the ocular posterior segment was supported. Further development of SCS injections for treatment of the ocular posterior segment is warranted.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.11-7525

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Seiler, G. S., Salmon, J. H., Mantuo, R., Feingold, S., Dayton, P. A., & Gilger, B. C.
Venue
Investigative Opthalmology & Visual Science
Published
2011-07-27
Volume
52
Issue
8
Pages
5730
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2062785231
Cited by
39
References
4
FWCI
1.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.