Equivalence of Biomechanical Changes Induced by Rapid and Standard Corneal Cross-linking, Using Riboflavin and Ultraviolet Radiation

Schumacher, Silvia, Oeftiger, Lydia, Mrochen, Michael · 2011 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: Ultraviolet (UV) corneal cross-linking is an accepted method for treating corneal ecstatic disorders. The authors evaluated whether a rapid treatment protocol (higher intensity and shorter irradiation time) could achieve the same increase in corneal stiffness as the currently used standard protocol. METHODS: Stress-strain measurements were performed on porcine corneal strips. The corneas (n = 72) were cut into three strips, each randomly receiving a different treatment: rapid (10 mW/cm(2), 9 minutes), standard (3 mW/cm(2), 30 minutes), or no (control, 0 mW/cm(2)) irradiation. After irradiation, the Young's modulus of each strip was determined. The results of the stress-strain measurements were analyzed statistically. RESULTS: Statistical analysis showed that, after irradiation, the median value of Young's modulus from both active treatment groups (rapid, 3.83 N/mm(2); standard, 3.88 N/mm(2)) was significantly higher (P < 0.05) than that of the control group (2.91 N/mm(2)). Treatment increased Young's modulus by a factor of 1.3. However, there was no significant difference (P = 0.43) between the rapid and standard groups in the median of Young's modulus. CONCLUSIONS: Rapid UV cross-linking treatment can be regarded as equivalent to the standard procedure in terms of increase in corneal stiffness. The new rapid protocol shortens the treatment duration by more than two thirds, from 30 to 9 minutes. The safety of the higher intensities must be addressed in further clinical studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.11-7818

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Die Reziprozitätsregel in der Photobiologie

    Schindl, A., Rosado-Schlosser, B., & Trautinger, F. (2001) · Der Hautarzt · doi:10.1007/s001050170065 · Cited by 58 · cited 1×

    “On the one hand, they support the direct application of the BunsenRoscoe law but, on the other hand, they also show that biological tissues possess a protective mechanism that can be damaged by electromagnetic radiation when the threshold intensity is exceeded for a prolonged period.(18) On the supposition that the Bu…”
    Background

Cited by

See all 221

Metadata

Authors
Schumacher, S., Oeftiger, L., & Mrochen, M.
Venue
Investigative Opthalmology & Visual Science
Published
2011-11-24
Volume
52
Issue
12
Pages
9048
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1980795519
Cited by
221
References
1
FWCI
12.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.