The Efficacy of Corneal Cross-Linking Shows a Sudden Decrease with Very High Intensity UV Light and Short Treatment Time

Wernli, Jeremy, Schumacher, Silvia, Spoerl, Eberhard, Mrochen, Michael · 2013 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: Standard treatment in cases of progressive keratectasia is UV-triggered corneal cross-linking. For irradiances larger than 10 mW/cm(2) and treatment times below 10 minutes, the scientific proof of a biomechanical strengthening effect is insufficient. The authors investigated the biomechanical strengthening of ex vivo corneal tissue treated with irradiances between 3 mW/cm(2) and 90 mW/cm(2) and illumination times from 30 minutes to 1 minute, respectively. METHODS: A total of 100 porcine eyes received riboflavin + UV treatment (constant irradiation dose of 5.4 J/cm(2)) with different intensities and illumination times and were randomly assigned into 10 groups. A control group (80 eyes) was not irradiated but underwent the same treatment otherwise. Young's modulus at 10% strain was determined for each strip after uniaxial stress-strain measurement. A Kruskal-Wallis test was used for statistical analysis. RESULTS: A statistically significant difference (α = 0.01) was found between the median value of Young's modulus of the treatment groups up to 45 mW/cm(2) (illumination times from 30 minutes to 2 minutes) compared with the control group. There was no statistically significant difference between the treatment groups from 50 mW/cm(2) up to 90 mW/cm(2) (illumination times of less than 2 minutes) and the control group. CONCLUSIONS: The ex vivo results of corneal cross-linking performed in porcine corneas show that the Bunsen-Roscoe reciprocity law is only valid for illumination intensities up to 40 to 50 mW/cm(2) and illumination times of more than 2 minutes. Further experiments are necessary to validate these results for in vivo human corneal tissue. Additionally, safety aspects at high intensities must be investigated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.12-11409

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 263

Metadata

Authors
Wernli, J., Schumacher, S., Spoerl, E., & Mrochen, M.
Venue
Investigative Opthalmology & Visual Science
Published
2013-02-12
Volume
54
Issue
2
Pages
1176
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1984537537
Cited by
263
References
9
FWCI
21.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Efficacy of Corneal Cross-Linking Shows a Sudden Decrease with Very High Intensity UV Light and Short Treatment Time. https://app.cochat.ai/papers/10.1167/iovs.12-11409
The paper
Wernli, J., Schumacher, S., Spoerl, E., & Mrochen, M. (2013). The Efficacy of Corneal Cross-Linking Shows a Sudden Decrease with Very High Intensity UV Light and Short Treatment Time. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.12-11409

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.