CoChat
Cited by 243

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Quantitative Measurements of Autofluorescence with the Scanning Laser Ophthalmoscope

Open access
Delori, François, Greenberg, Jonathan P., Woods, Russell L., Fischer, Jörg, Duncker, Tobias, Sparrow, Janet, Smith, R. Theodore · 2011 · Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To evaluate the feasibility and reliability of a standardized approach for quantitative measurements of fundus autofluorescence (AF) in images obtained with a confocal scanning laser ophthalmoscope (cSLO). METHODS: AF images (30°) were acquired in 34 normal subjects (age range, 20-55 years) with two different cSLOs (488-nm excitation) equipped with an internal fluorescent reference to account for variable laser power and detector sensitivity. The gray levels (GLs) of each image were calibrated to the reference, the zero GL, and the magnification, to give quantified autofluorescence (qAF). Images from subjects and fixed patterns were used to test detector linearity with respect to fluorescence intensity, the stability of qAF with change in detector gain, field uniformity, effect of refractive error, and repeatability. RESULTS: qAF was independent of detector gain and laser power over clinically relevant ranges, provided that detector gain was adjusted to maintain exposures within the linear detection range (GL < 175). Field uniformity was better than 5% in a central 20°-diameter circle but decreased more peripherally. The theoretical inverse square magnification correction was experimentally verified. Photoreceptor bleaching for at least 20 seconds was performed. Repeatability (95% confidence interval) for same day and different-day retests of qAF was ±6% to ±14%. Agreement (95% confidence interval) between the two instruments was <11%. CONCLUSIONS: Quantitative AF imaging appears feasible. It may enhance understanding of retinal degeneration, serve as a diagnostic aid and as a sensitive marker of disease progression, and provide a tool to monitor the effects of therapeutic interventions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.11-8319

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 243

Metadata

Authors
Delori, F., Greenberg, J. P., Woods, R. L., Fischer, J., Duncker, T., Sparrow, J., & Smith, R. T.
Venue
Investigative Opthalmology & Visual Science
Published
2011-12-09
Volume
52
Issue
13
Pages
9379
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1992364186
Cited by
243
References
4
FWCI
9.65
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative Measurements of Autofluorescence with the Scanning Laser Ophthalmoscope. https://app.cochat.ai/papers/10.1167/iovs.11-8319
The paper
Delori, F., Greenberg, J. P., Woods, R. L., Fischer, J., Duncker, T., Sparrow, J., & Smith, R. T. (2011). Quantitative Measurements of Autofluorescence with the Scanning Laser Ophthalmoscope. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.11-8319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.