The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Enhanced Depth Imaging Optical Coherence Tomography in Type 2 Diabetes
Open accessAbstract
PURPOSE: To investigate the changes in macular choroidal thickness in eyes with various stages of diabetic retinopathy, using enhanced depth imaging optical coherence tomography (EDI OCT). METHODS: Sixty-three consecutive diabetic patients--who presented without diabetic retinopathy (NDR); with diabetic retinopathy (nonproliferative diabetic retinopathy [NPDR]) and no clinically significant macular edema (CSME-); or with NDPR and clinically significant macular edema (CSME+)--underwent EDI OCT. Twenty-one age- and sex-matched healthy subjects (21 eyes) also underwent EDI OCT. RESULTS: A total of 63 eyes of 63 consecutive diabetic patients (26 female [41.2%]; mean age 65 ± 9 years, range 48-83 years) were included in the analysis. Mean best-corrected visual acuity was 0.13 ± 0.25 LogMAR (range 0-1). Mean CMT was 272.5 ± 16.2 μm in 21 NDR eyes, 294.5 ± 23.5 μm in 21 NPDR/CSME- eyes, and 385.6 ± 75.1 μm in 21 NPDR/CSME+ eyes. There was no difference in mean subfoveal choroidal thickness among each diabetic group (238.4 ± 47.9 μm [NDR], 207.0 ± 55.9 μm [NPDR/CSME-], 190.8 ± 48.4 μm [NPDR/CSME+]; P = 0.23). The mean subfoveal choroidal thickness was significantly reduced in each diabetic group compared with the control group (309.8 ± 58.5 μm, P < 0.001). CONCLUSIONS: In diabetic eyes, there is an overall thinning of the choroid on EDI OCT. A decreased choroidal thickness may lead to tissue hypoxia and consequently increase the level of VEGF, resulting in the breakdown of the blood-retinal barrier and development of macular edema.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Enhanced Depth Imaging Spectral-Domain Optical Coherence Tomography
Spaide, R. F., Koizumi, H., & Pozonni, M. C. (2008) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.05.032 · Cited by 2,180
Topography of diabetic macular edema with optical coherence tomography
Hee, M. R., Puliafito, C. A., Duker, J. S., Reichel, E., Coker, J. G., Wilkins, J. R., Schuman, J. S., Swanson, E. A., & Fujimoto, J. G. (1998) · Ophthalmology · doi:10.1016/s0161-6420(98)93601-6 · Cited by 633
Levin, L. A., NILSSON, S. F. E., Hoeve, J. N. V., Wu, S. M.-S., Kaufman, P. L., & Alm, A. (2011) · Andalas University Repository (Andalas University) · Cited by 578
Early breakdown of the blood-retinal barrier in diabetes.
Cunha-Vaz, J., Faria de Abreu, J. R., & Campos, A. J. (1975) · British Journal of Ophthalmology · doi:10.1136/bjo.59.11.649 · Cited by 562
Hypoxic Regulation of Vascular Endothelial Growth Factor in Retinal Cells
Aiello, L. P. (1995) · Archives of Ophthalmology · doi:10.1001/archopht.1995.01100120068012 · Cited by 560
Bresnick, G. H. (1986) · Ophthalmology · doi:10.1016/s0161-6420(86)33650-9 · Cited by 410
Kim, S.-W., Oh, J., Kwon, S.-S., Yoo, J., & Huh, K. (2011) · Retina · doi:10.1097/iae.0b013e31821801c5 · Cited by 312
Diabetic choroidopathy. Light and electron microscopic observations of seven cases.
Hidayat, A. A., & Fine, B. S. (1985) · PubMed · Cited by 281
High-resolution histologic analysis of the human choroidal vasculature.
McLeod, D. S., & Lutty, G. A. (1994) · PubMed · Cited by 261
Cited by
Diabetic retinopathy: current understanding, mechanisms, and treatment strategies
Duh, E. J., Sun, J. K., & Stitt, A. W. (2017) · JCI Insight · doi:10.1172/jci.insight.93751 · Cited by 1,057
Agemy, S. A., Scripsema, N. K., Shah, C. M., Chui, T., Garcia, P. M., Lee, J. G., Gentile, R. C., Hsiao, Y.-S., Zhou, Q., Ko, T., et al. (2015) · Retina · doi:10.1097/iae.0000000000000862 · Cited by 472
Kim, J. T., Lee, D. H., Joe, S. G., Kim, J.-G., & Yoon, Y. H. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-11503 · Cited by 322
Ferrara, D., Waheed, N. K., & Duker, J. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.10.002 · Cited by 265
Exploring choroidal angioarchitecture in health and disease using choroidal vascularity index
Agrawal, R., Ding, J., Sen, P., Rousselot, A., Chan, A., Nivison-Smith, L., Wei, X., Mahajan, S., Kim, R., Mishra, C., et al. (2020) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100829 · Cited by 255
Metadata
- Authors
- Querques, G., Lattanzio, R., Querques, L., Del Turco, C., Forte, R., Pierro, L., Souied, E. H., & Bandello, F.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2012-09-07
- Volume
- 53
- Issue
- 10
- Pages
- 6017
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2092464362
- Cited by
- 267
- References
- 16
- FWCI
- 14.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Depth Imaging Optical Coherence Tomography in Type 2 Diabetes. https://app.cochat.ai/papers/10.1167/iovs.12-9692
- The paper
- Querques, G., Lattanzio, R., Querques, L., Del Turco, C., Forte, R., Pierro, L., Souied, E. H., & Bandello, F. (2012). Enhanced Depth Imaging Optical Coherence Tomography in Type 2 Diabetes. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.12-9692
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.