Axial Eye Growth and Refractive Error Development Can Be Modified by Exposing the Peripheral Retina to Relative Myopic or Hyperopic Defocus
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: Bifocal contact lenses were used to impose hyperopic and myopic defocus on the peripheral retina of marmosets. Eye growth and refractive state were compared with untreated animals and those treated with single-vision or multizone contact lenses from earlier studies. METHODS: Thirty juvenile marmosets wore one of three experimental annular bifocal contact lens designs on their right eyes and a plano contact lens on the left eye as a control for 10 weeks from 70 days of age (10 marmosets/group). The experimental designs had plano center zones (1.5 or 3 mm) and +5 diopters [D] or -5 D in the periphery (referred to as +5 D/1.5 mm, +5 D/3 mm and -5 D/3 mm). We measured the central and peripheral mean spherical refractive error (MSE), vitreous chamber depth (VC), pupil diameter (PD), calculated eye growth, and myopia progression rates prior to and during treatment. The results were compared with age-matched untreated (N=25), single-vision positive (N=19), negative (N=16), and +5/-5 D multizone lens-reared marmosets (N=10). RESULTS: At the end of treatment, animals in the -5 D/3 mm group had larger (P<0.01) and more myopic eyes (P<0.05) than animals in the +5 D/1.5 mm group. There was a dose-dependent relationship between the peripheral treatment zone area and the treatment-induced changes in eye growth and refractive state. Pretreatment ocular growth rates and baseline peripheral refraction accounted for 40% of the induced refraction and axial growth rate changes. CONCLUSIONS: Eye growth and refractive state can be manipulated by altering peripheral retinal defocus. Imposing peripheral hyperopic defocus produces axial myopia, whereas peripheral myopic defocus produces axial hyperopia. The effects are smaller than using single-vision contact lenses that impose full-field defocus, but support the use of bifocal or multifocal contact lenses as an effective treatment for myopia control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In a Matter of Minutes, the Eye Can Know Which Way to Grow
Zhu, X., Park, T. W., Winawer, J., & Wallman, J. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0956 · Cited by 179 · cited 1×
“In yet another study, only a few minutes of exposure to myopic defocus each day was effective in preventing the response to hours of hyperopic defocus, which produces axial elongation and myopia.(55) We also considered the effect of the duration of bifocal lenses wear by examining growth rate changes throughout treatm…”
Cited by
IMI – Report on Experimental Models of Emmetropization and Myopia
Troilo, D., Smith, E. L., Nickla, D. L., Ashby, R., Tkatchenko, A. V., Ostrin, L. A., Gawne, T. J., Pardue, M. T., Summers, J. A., Kee, C.-S., et al. (2019) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.18-25967 · Cited by 487
“In guinea pigs and marmosets, the relative effectiveness of the two power zones in controlling axial growth appeared to be linearly related to the relative surface area of the lens associated with each power component.(320,324) That does not appear to be the case in rhesus monkeys,(323) although there were several met…”
BackgroundSelf-citationAnimal models in myopia research
Schaeffel, F., & Feldkaemper, M. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12312 · Cited by 188
Metadata
- Authors
- Benavente-Perez, A., Nour, A., & Troilo, D.
- Venue
- Investigative Ophthalmology & Visual Science
- Published
- 2014-09-04
- Volume
- 55
- Issue
- 10
- Pages
- 6765-6773
- ISSN
- 0146-0404 (ISSN-L)
- OpenAlex
- W2334565254
- Cited by
- 234
- References
- 1
- FWCI
- 6.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.