The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
In Vivo Imaging of Human Cone Photoreceptor Inner Segments
Open accessAbstract
PURPOSE: An often overlooked prerequisite to cone photoreceptor gene therapy development is residual photoreceptor structure that can be rescued. While advances in adaptive optics (AO) retinal imaging have recently enabled direct visualization of individual cone and rod photoreceptors in the living human retina, these techniques largely detect strongly directionally-backscattered (waveguided) light from normal intact photoreceptors. This represents a major limitation in using existing AO imaging to quantify structure of remnant cones in degenerating retina. METHODS: Photoreceptor inner segment structure was assessed with a novel AO scanning light ophthalmoscopy (AOSLO) differential phase technique, that we termed nonconfocal split-detector, in two healthy subjects and four subjects with achromatopsia. Ex vivo preparations of five healthy donor eyes were analyzed for comparison of inner segment diameter to that measured in vivo with split-detector AOSLO. RESULTS: Nonconfocal split-detector AOSLO reveals the photoreceptor inner segment with or without the presence of a waveguiding outer segment. The diameter of inner segments measured in vivo is in good agreement with histology. A substantial number of foveal and parafoveal cone photoreceptors with apparently intact inner segments were identified in patients with the inherited disease achromatopsia. CONCLUSIONS: The application of nonconfocal split-detector to emerging human gene therapy trials will improve the potential of therapeutic success, by identifying patients with sufficient retained photoreceptor structure to benefit the most from intervention. Additionally, split-detector imaging may be useful for studies of other retinal degenerations such as AMD, retinitis pigmentosa, and choroideremia where the outer segment is lost before the remainder of the photoreceptor cell.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human photoreceptor topography
Curcio, C. A., Sloan, K. R., Kalina, R. E., & Hendrickson, A. E. (1990) · Journal of Comparative Neurology · doi:10.1002/cne.902920402 · Cited by 2,790
Self-citationCowden, R. R., & Weibel, E. R. (1982) · Transactions of the American Microscopical Society · doi:10.2307/3225581 · Cited by 1,191
Retinal repair by transplantation of photoreceptor precursors
MacLaren, R. E., Pearson, R. A., MacNeil, A., Douglas, R. H., Salt, T. E., Akimoto, M., Swaroop, A., Sowden, J. C., & Ali, R. R. (2006) · Nature · doi:10.1038/nature05161 · Cited by 1,096
Adaptive optics scanning laser ophthalmoscopy
Roorda, A., Romero-Borja, F., Donnelly III, W. J., Queener, H., Hebert, T. J., & Campbell, M. C. W. (2002) · Optics Express · doi:10.1364/oe.10.000405 · Cited by 967
Photoreceptor loss in age-related macular degeneration.
Curcio, C. A., Medeiros, N. E., & Millican, C. L. (1996) · PubMed · Cited by 802
Self-citationMacLaren, R. E., Groppe, M., Barnard, A. R., Cottriall, C. L., Tolmachova, T., Seymour, L., Clark, K. R., During, M. J., Cremers, F. P. M., Black, G. C. M., et al. (2014) · The Lancet · doi:10.1016/s0140-6736(13)62117-0 · Cited by 796
Aberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Curcio, C. A., Millican, C. L., Allen, K. A., & Kalina, R. E. (1993) · PubMed · Cited by 678
Self-citationConfocal scanning laser ophthalmoscope
Webb, R. H., Hughes, G. W., & Delori, F. C. (1987) · Applied Optics · doi:10.1364/ao.26.001492 · Cited by 597
Restoration of vision after transplantation of photoreceptors
Pearson, R. A., Barber, A. C., Rizzi, M., Hippert, C., Xue, T., West, E. L., Duran, Y., Smith, A. J., Chuang, J. Z., Azam, S. A., et al. (2012) · Nature · doi:10.1038/nature10997 · Cited by 493
Cited by
Stargardt disease: clinical features, molecular genetics, animal models and therapeutic options
Tanna, P., Strauss, R. W., Fujinami, K., & Michaelides, M. (2017) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2016-308823 · Cited by 370
The cone dysfunction syndromes: Table 1
Aboshiha, J., Dubis, A. M., Carroll, J., Hardcastle, A. J., & Michaelides, M. (2016) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-306505 · Cited by 314
Self-citationAdaptive optics imaging of the human retina
Burns, S. A., Elsner, A. E., Sapoznik, K. A., Warner, R. L., & Gast, T. J. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.08.002 · Cited by 263
Inherited Retinal Degenerations: Current Landscape and Knowledge Gaps
Duncan, J. L., Pierce, E. A., Laster, A. M., Daiger, S. P., Birch, D. G., Ash, J. D., Iannaccone, A., Flannery, J. G., Sahel, J. A., Zack, D. J., et al. (2018) · Translational Vision Science & Technology · doi:10.1167/tvst.7.4.6 · Cited by 257
STARNES, A. C., HUISINGH, C., MCGWIN, G., SLOAN, K. R., ABLONCZY, Z., SMITH, R. T., CURCIO, C. A., & ACH, T. (2016) · Visual Neuroscience · doi:10.1017/s0952523815000310 · Cited by 46
Self-citation
Metadata
- Authors
- Scoles, D., Sulai, Y. N., Langlo, C. S., Fishman, G. A., Curcio, C. A., Carroll, J., & Dubra, A.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2014-07-11
- Volume
- 55
- Issue
- 7
- Pages
- 4244
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2107546491
- Cited by
- 380
- References
- 39
- FWCI
- 13.02
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.