Automatic Identification of Reticular Pseudodrusen Using Multimodal Retinal Image Analysis
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
PURPOSE: To examine human performance and agreement on reticular pseudodrusen (RPD) detection and quantification by using single- and multimodality grading protocols and to describe and evaluate a machine learning system for the automatic detection and quantification of reticular pseudodrusen by using single- and multimodality information. METHODS: Color fundus, fundus autofluoresence, and near-infrared images of 278 eyes from 230 patients with or without presence of RPD were used in this study. All eyes were scored for presence of RPD during single- and multimodality setups by two experienced observers and a developed machine learning system. Furthermore, automatic quantification of RPD area was performed by the proposed system and compared with human delineations. RESULTS: Observers obtained a higher performance and better interobserver agreement for RPD detection with multimodality grading, achieving areas under the receiver operating characteristic (ROC) curve of 0.940 and 0.958, and a κ agreement of 0.911. The proposed automatic system achieved an area under the ROC of 0.941 with a multimodality setup. Automatic RPD quantification resulted in an intraclass correlation (ICC) value of 0.704, which was comparable with ICC values obtained between single-modality manual delineations. CONCLUSIONS: Observer performance and agreement for RPD identification improved significantly by using a multimodality grading approach. The developed automatic system showed similar performance as observers, and automatic RPD area quantification was in concordance with manual delineations. The proposed automatic system allows for a fast and accurate identification and quantification of RPD, opening the way for efficient quantitative imaging biomarkers in large data set analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
Bird, A. C., Bressler, N. M., Bressler, S. B., Chisholm, I. H., Coscas, G., Davis, M. D., de Jong, P. T. V. M., Klaver, C. C. W., Klein, B. E. K., Klein, R., et al. (1995) · Survey of Ophthalmology · doi:10.1016/s0039-6257(05)80092-x · Cited by 1,926
Self-citationAge-related macular degeneration
de Jong, P. T. V. M. (2006) · New England Journal of Medicine · doi:10.1056/nejmra062326 · Cited by 787
Cited by
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
Subretinal drusenoid deposits AKA pseudodrusen
Spaide, R. F., Ooto, S., & Curcio, C. A. (2018) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2018.05.005 · Cited by 292
González-Gonzalo, C., Thee, E. F., Klaver, C. C. W., Lee, A. Y., Schlingemann, R. O., Tufail, A., Verbraak, F., & Sánchez, C. I. (2022) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.101034 · Cited by 103
“In van Grinsven et al. (2015), a ML model was proposed to detect the presence of reticular pseudodrusen using multimodal information from CFP, FAF, and NIF, and showed that it achieved higher performance than that obtained when using images from each modality separately.”
Self-citationBiarnés, M., Colijn, J. M., Sousa, J., Ferraro, L. L., Garcia, M., Verzijden, T., Meester-Smoor, M. A., Delcourt, C., Klaver, C. C. W., den Hollander, A. I., et al. (2020) · Ophthalmology Retina · doi:10.1016/j.oret.2020.04.014 · Cited by 40
Self-citation
Metadata
- Authors
- van Grinsven, M. J. J. P., Buitendijk, G. H. S., Brussee, C., van Ginneken, B., Hoyng, C. B., Theelen, T., Klaver, C. C. W., & Sanchez, C. I.
- Venue
- Investigative Ophthalmology & Visual Science
- Published
- 2015-01-08
- Volume
- 56
- Issue
- 1
- Pages
- 633-639
- ISSN
- 0146-0404 (ISSN-L)
- OpenAlex
- W2320938042
- Cited by
- 42
- References
- 3
- FWCI
- 2.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.