CoChat

Real-Time Monitoring of Suprachoroidal Space (SCS) Following SCS Injection Using Ultra-High Resolution Optical Coherence Tomography in Guinea Pig Eyes

Gu, Bing, Liu, Jinkun, Li, Xiaoli, Ma, QingKai, Shen, Meixiao, Cheng, Lingyun · 2015 · Investigative Opthalmology & Visual Science
Cited by 49

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

PURPOSE: To monitor the change of suprachoroidal space (SCS) using ultra high resolution-optical coherence tomography (UHR-OCT) following SCS injection with different drug formulations. METHODS: An amount of 10 or 20 μL of saline or indocyanine green (ICG) or triamcinolone acetonide (TA) suspension (40 or 80 mg/mL) was injected suprachoroidally into the guinea pig eye with a 30-gauge needle. Immediately after injection, the eyes were imaged by UHR-OCT from 60 minutes up to 24 hours. At each time point, the SCS area on each OCT cross-section was measured in pixels with Image J and the area change from the baselines was analyzed over time. RESULTS: A 20-μL injection produced 130% to 200% SCS expansion compared to a 10-μL injection for saline and TA suspension (P < 0.01). After SCS injection, the time that expansion persisted was formulation dependent. Thus, expansion in response to injection of TA suspension, ICG, and saline persisted for 24 hours, 180 minutes, and 60 minutes, respectively. Moreover, ICG injection produced a significantly larger area of distribution in the SCS than the TA suspension (0.626 vs. 0.275 cm(2), P < 0.0001). CONCLUSIONS: The SCS is expandable and can recover to preinjection status after injected fluid is cleared by physiological processes. The injection-induced SCS expansion is volume-dependent, and the drug/dye retained in the SCS is formulation-dependent. The current injection technique with a volume of 20 μL or less is well tolerated in guinea pig eyes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.15-16597

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 49

Metadata

Authors
Gu, B., Liu, J., Li, X., Ma, Q., Shen, M., & Cheng, L.
Venue
Investigative Opthalmology & Visual Science
Published
2015-06-03
Volume
56
Issue
6
Pages
3623
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W1529221294
Cited by
49
References
3
FWCI
3.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.