Purpose: After promising results of an exploratory study, this study was designed to assess the safety and efficacy of transcorneal electrical stimulation (TES) over 1 year in patients with retinitis pigmentosa (RP). Methods: We included 52 RP patients in this prospective, randomized, partially-masked study which was done in accordance with rules of good clinical practice. Transcorneal electrical stimulation by Okustim was applied monocularly for 30 minutes per week for 52 consecutive weeks. Patients were assigned randomly to the groups: sham, 150%, or 200% of individual electrical phosphene threshold (EPT). Visual acuity (retroilluminated Snellen charts), visual field (VF; Octopus 900), electroretinography (ERG), rod and cone full-field stimulus threshold, EPTs and IOP were assessed. Primary outcome measures were VF area; secondary outcome measures were development of ERG parameters. Results: The application of TES was tolerated well. Dry eye symptoms (31 of 52 patients) were registered as the main adverse event. Throughout the study period, the VF area showed only a trend for prevention of VF loss in the 200% group (P = 0.24). A significant improvement of light-adapted single flash b-wave was noted for the 200% (P < 0.0001) and 150% (P = 0.006) groups compared to the sham group. Tendencies of improved function were observed for scotopic b-wave amplitude for the 200% group (P = 0.097). Other examination methods did not reach statistical significance. Conclusions: The safety and acceptable tolerability of weekly TES self-administered by patients at home was confirmed over the course of 1 year. Objectively measured improvements in retinal function with ERG provide support for the potential benefits of TES for RP patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1167/iovs.16-19906

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 98

Metadata

Authors
Schatz, A., Pach, J., Gosheva, M., Naycheva, L., Willmann, G., Wilhelm, B., Peters, T., Bartz-Schmidt, K. U., Zrenner, E., Messias, A., & Gekeler, F.
Venue
Investigative Opthalmology & Visual Science
Published
2017-01-18
Volume
58
Issue
1
Pages
257
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2581794159
Cited by
98
References
2
FWCI
3.40
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transcorneal Electrical Stimulation for Patients With Retinitis Pigmentosa: A Prospective, Randomized, Sham-Controlled Follow-up Study Over 1 Year. https://app.cochat.ai/papers/10.1167/iovs.16-19906
The paper
Schatz, A., Pach, J., Gosheva, M., Naycheva, L., Willmann, G., Wilhelm, B., Peters, T., Bartz-Schmidt, K. U., Zrenner, E., Messias, A., & Gekeler, F. (2017). Transcorneal Electrical Stimulation for Patients With Retinitis Pigmentosa: A Prospective, Randomized, Sham-Controlled Follow-up Study Over 1 Year. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.16-19906

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.