Automated Staging of Age-Related Macular Degeneration Using Optical Coherence Tomography
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Purpose: To evaluate a machine learning algorithm that automatically grades age-related macular degeneration (AMD) severity stages from optical coherence tomography (OCT) scans. Methods: A total of 3265 OCT scans from 1016 patients with either no signs of AMD or with signs of early, intermediate, or advanced AMD were randomly selected from a large European multicenter database. A machine learning system was developed to automatically grade unseen OCT scans into different AMD severity stages without requiring retinal layer segmentation. The ability of the system to identify high-risk AMD stages and to assign the correct severity stage was determined by using receiver operator characteristic (ROC) analysis and Cohen's κ statistics (κ), respectively. The results were compared to those of two human observers. Reproducibility was assessed in an independent, publicly available data set of 384 OCT scans. Results: The system achieved an area under the ROC curve of 0.980 with a sensitivity of 98.2% at a specificity of 91.2%. This compares favorably with the performance of human observers who achieved sensitivities of 97.0% and 99.4% at specificities of 89.7% and 87.2%, respectively. A good level of agreement with the reference was obtained (κ = 0.713) and was in concordance with the human observers (κ = 0.775 and κ = 0.755, respectively). Conclusions: A machine learning system capable of automatically grading OCT scans into AMD severity stages was developed and showed similar performance as human observers. The proposed automatic system allows for a quick and reliable grading of large quantities of OCT scans, which could increase the efficiency of large-scale AMD studies and pave the way for AMD screening using OCT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The random subspace method for constructing decision forests
Ho, T. K. (1998) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.709601 · Cited by 6,842
Ranibizumab for Neovascular Age-Related Macular Degeneration
Rosenfeld, P. J., Brown, D. M., Heier, J. S., Boyer, D. S., Kaiser, P. K., Chung, C. Y., & Kim, R. Y. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054481 · Cited by 5,886
Ranibizumab and bevacizumab for neovascular age-related macular degeneration
(2011) · New England Journal of Medicine · doi:10.1056/nejmoa1102673 · Cited by 2,669
Efficient Visual Search of Videos Cast as Text Retrieval
Sivic, J., & Zisserman, A. (2009) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2008.111 · Cited by 499
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Genetic Risk of Age-related Maculopathy: Population-Based Familial Aggregation Study
Klaver, C. C. W. (1998) · Archives of Ophthalmology · doi:10.1001/archopht.116.12.1646 · Cited by 323
Cited by
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
“This screening system was developed on a fairly large database of 3265 OCT scans (Venhuizen et al., 2017).”
Macular OCT Classification Using a Multi-Scale Convolutional Neural Network Ensemble
Rasti, R., Rabbani, H., Mehridehnavi, A., & Hajizadeh, F. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2780115 · Cited by 298
Treder, M., Lauermann, J. L., & Eter, N. (2018) · Graefe's Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-017-3850-3 · Cited by 242
Deep learning based retinal OCT segmentation
Pekala, M., Joshi, N., Liu, T. Y. A., Bressler, N. M., DeBuc, D. C., & Burlina, P. (2019) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2019.103445 · Cited by 206
González-Gonzalo, C., Thee, E. F., Klaver, C. C. W., Lee, A. Y., Schlingemann, R. O., Tufail, A., Verbraak, F., & Sánchez, C. I. (2022) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2021.101034 · Cited by 103
“While only few observer studies have been performed in ophthalmology, they have shown that the performance AI systems can exceed that of observers in different tasks (Liefers et al., 2020, 2021; Chen et al., 2021; González-Gonzalo et al., 2020b; Venhuizen et al., 2017; van Grinsven et al., 2013, 2015).”
Self-citation
Metadata
- Authors
- Venhuizen, F. G., van Ginneken, B., van Asten, F., van Grinsven, M. J. J. P., Fauser, S., Hoyng, C. B., Theelen, T., & Sánchez, C. I.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2017-04-24
- Volume
- 58
- Issue
- 4
- Pages
- 2318
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2608603966
- Cited by
- 123
- References
- 6
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated Staging of Age-Related Macular Degeneration Using Optical Coherence Tomography. https://app.cochat.ai/papers/10.1167/iovs.16-20541
- The paper
- Venhuizen, F. G., van Ginneken, B., van Asten, F., van Grinsven, M. J. J. P., Fauser, S., Hoyng, C. B., Theelen, T., & Sánchez, C. I. (2017). Automated Staging of Age-Related Macular Degeneration Using Optical Coherence Tomography. Investigative Opthalmology & Visual Science. https://doi.org/10.1167/iovs.16-20541
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.