Analyzing and Predicting Visual Acuity Outcomes of Anti-VEGF Therapy by a Longitudinal Mixed Effects Model of Imaging and Clinical Data
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: We develop a longitudinal statistical model describing best-corrected visual acuity (BCVA) changes in anti-VEGF therapy in relation to imaging data, and predict the future BCVA outcome for individual patients by combining population-wide trends and initial subject-specific time points. Methods: Automatic segmentation algorithms were used to measure intraretinal (IRF) and subretinal (SRF) fluid volume on monthly spectral-domain optical coherence tomography scans of eyes with central retinal vein occlusion (CRVO) receiving standardized anti-VEGF treatment. The trajectory of BCVA over time was modeled as a multivariable repeated-measure mixed-effects regression model including fluid volumes as covariates. Subject-specific BCVA trajectories and final treatment outcomes were predicted using a population-wide model and individual observations from early follow-up. Results: A total of 193 eyes (one per patient, 12-month follow-up, 2420 visits) were analyzed. The population-wide mixed model revealed that the impact of fluid on BCVA is highest for IRF in the central millimeter around the fovea, with -31.17 letters/mm3 (95% confidence interval [CI], -39.70 to -23.32), followed by SRF in the central millimeter, with -17.50 letters/mm3 (-31.17 to -4.60) and by IRF in the parafovea, with -2.87 letters/mm3 (-4.71 to -0.44). The influence of SRF in the parafoveal area was -1.24 letters/mm3 (-3.37-1.05). The conditional R2 of the model, including subject-specific deviations, was 0.887. The marginal R2 considering the population-wide trend and fluid changes was 0.109. BCVA at 1 year could be predicted for an individual patient after three visits with a mean absolute error of six letters and a predicted R2 of 0.658 using imaging information. Conclusions: The mixed-effects model revealed that retinal fluid volumes and population-wide trend only explains a small proportion of the variation in BCVA. Individual BCVA outcomes after 1 year could be predicted from initial BCVA and fluid measurements combined with the population-wide model. Accounting for fluid in the predictive model increased prediction accuracy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Approximate Distribution of Estimates of Variance Components
Satterthwaite, F. E. (1946) · Biometrics Bulletin · doi:10.2307/3002019 · Cited by 4,373
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390 · cited 2×
“, photoreceptor damage).(3) However, the extent of each factor’s contribution is unclear and the interplay between imaging biomarkers, visual function, and treatment response remains poorly understood.”
BackgroundSelf-citation(2014) · Ophthalmology · doi:10.1016/j.ophtha.2013.11.031 · Cited by 283
Cited by
Introduction to Machine Learning, Neural Networks, and Deep Learning.
Choi, R. Y., Coyner, A. S., Kalpathy–Cramer, J., Chiang, M. F., & Campbell, J. P. (2020) · PubMed · doi:10.1167/tvst.9.2.14 · Cited by 1,012
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
Self-citationSchmidt-Erfurth, U., Garcia-Arumi, J., Gerendas, B. S., Midena, E., Sivaprasad, S., Tadayoni, R., Wolf, S., & Loewenstein, A. (2019) · Ophthalmologica · doi:10.1159/000502041 · Cited by 284
Self-citationRETOUCH: The Retinal OCT Fluid Detection and Segmentation Benchmark and Challenge
Bogunovic, H., Venhuizen, F., Klimscha, S., Apostolopoulos, S., Bab-Hadiashar, A., Bagci, U., Beg, M. F., Bekalo, L., Chen, Q., Ciller, C., et al. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2901398 · Cited by 273
Self-citationExploiting epistemic uncertainty of anatomy segmentation for anomaly detection in retinal OCT
Seebock, P., Orlando, J. I., Schlegl, T., Waldstein, S. M., Bogunovic, H., Klimscha, S., Langs, G., & Schmidt-Erfurth, U. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2919951 · Cited by 164
“Presence or changes in some of these features have been shown to correlate with visual function or disease progression [29].”
BackgroundSelf-citationModeling Disease Progression in Retinal OCTs with Longitudinal Self-supervised Learning
Rivail, A., Schmidt-Erfurth, U., Vogl, W.-D., Waldstein, S. M., Riedl, S., Grechenig, C., Wu, Z., & Bogunovic, H. (2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-32281-6_5 · Cited by 25
“It enables personalized precision medicine [9] and it is a great source for automated image analysis.”
BackgroundSelf-citation
Metadata
- Authors
- Vogl, W.-D., Waldstein, S. M., Gerendas, B. S., Schlegl, T., Langs, G., & Schmidt-Erfurth, U.
- Venue
- Investigative Opthalmology & Visual Science
- Published
- 2017-08-24
- Volume
- 58
- Issue
- 10
- Pages
- 4173
- ISSN
- 0146-0404 (ISSN-L)
- 1552-5783
- OpenAlex
- W2738980709
- Cited by
- 37
- References
- 3
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.