CoChat

MEASUREMENT OF SMALL QUANTITIES OF INSULIN-LIKE ACTIVITY WITH RAT ADIPOSE TISSUE. IV. SERUM INSULIN-LIKE ACTIVITY AND TUMOR INSULIN CONTENT IN PATIENTS WITH FUNCTIONING ISLET-CELL TUMORS*

Open access
Steinke, Jurgen, Soeldner, J. Stuart, Renold, Albert E. · 1963 · Journal of Clinical Investigation
Cited by 119

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

provided through the courtesy of the attending physicians.' Case reports concerning 4 patients of the present series have been published (2-4).Preoperatively, up to 6 serum samples were obtained in each of the 23 patients, either in the fasting state or during hypoglycemia.Fasting serum samples were also obtained 7 days after surgery or later, but only in patients who did not receive insulin treatment.Two patients died in the immediate postoperative period, 3 received insulin, and 4 were either inoperable or refused surgery, the diagnosis being proven at autopsy.Accordingly, follow-up samples were available in only 14 pa- tients.Furthermore, in the preoperative period, 6 patients received rapid iv glucose loading (0.5 g glucose per kg of body weight) with samples for serum ILA drawn before, and 10, 20, and 60 minutes after infusion.Blood specimens were allowed to clot at room temperature, and the serum was separated by centrifugation.Serum glu- cose was determined on sample by the Somogyi-Nelson method (5, 6), and the remainder was kept frozen at -20' C for bioassay.Portions of the islet-cell tumors were collected either immediately after surgical removal of the tumor, or at autopsy, and were quickly frozen.Adjacent pancreas, or metastatic tissue, or both were obtained and stored similarly.For control purposes, pancreas from nondia- betic subjects, and youth-onset and maturity-onset diabetic patients were obtained at autopsy 6 hours or less after death and treated in an identical manner.Insulin ex- traction of all tissues was performed in the cold by the acid ethanol technique (7), or by a cationic exchange resin method, or both.The resin employed was Dowex 50W-X2 which was prepared fresh each week as previously described (8).The frozen tissue was homogenized for 3 to 5 minutes in a Waring Blendor, with 10 ml of cold saline added for each gram of tissue.The homogenate was pressed through cheesecloth, and the filtrate was collected in a beaker already containing 20 ml of prepared I We gratefully acknowledge the collaboration of Drs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci104816

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 119

Metadata

Authors
Steinke, J., Soeldner, J. S., & Renold, A. E.
Venue
Journal of Clinical Investigation
Published
1963-08-01
Volume
42
Issue
8
Pages
1322-1329
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2054413390
Cited by
119
References
1
FWCI
101.43
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.