CoChat

Direct measurement of the rates of synthesis of plasma proteins in control subjects and patients with gastrointestinal protein loss

Open access
Wochner, R. Dean, Weissman, Sherman M., Waldmann, Thomas A., Houston, Delores, Berlin, Nathaniel I. · 1968 · Journal of Clinical Investigation
Cited by 69

The DOI matches its Crossref record.

Abstract

The guanido carbon of hepatic arginine is the common precursor of urea and of the arginine of plasma proteins synthesized in the liver. It is possible to measure the momentary synthetic rates of plasma proteins by "pulse labeling" this arginine pool with bicarbonate-(14)C. In the current study, this method has been adapted in order to use urinary urea data and was applied to control subjects and patients with gastrointestinal protein loss. The assumptions required for this determination are discussed. There was close agreement between albumin synthetic rates measured by this method and albumin catabolic rates derived from simultaneous albumin-(131)I studies, supporting the validity of the method and suggesting that there is relatively little fluctuation in the rate of albumin synthesis from time to time. The albumin synthetic rates in six control subjects averaged 5.8 mg/kg per hr, while those of five patients with gastrointestinal protein loss averaged 7.2 mg/kg per hr. Thus in these patients, there was relatively little acceleration of albumin synthesis in response to continued loss of plasma proteins into the gastrointestinal tract. Fibrinogen synthetic rates averaged 1.9 mg/kg per hr in five control subjects and 3.2 mg/kg per hr in five patients with gastrointestinal protein loss. Transferrin synthetic rates exhibited considerable individual variation in both groups and averaged 0.24 mg/kg per hr in four control subjects and 0.31 mg/kg per hr in five patients with gastrointestinal protein loss. The method employed in this study offers several advantages in studying plasma protein metabolism. It provides a direct measurement of protein synthesis, applicable to several proteins simultaneously, does not require a long-term steady state in the metabolism of the proteins, and is capable of measuring short-term fluctuations in synthetic rates. Therefore, this approach is applicable to the investigation of the physiological factors controlling the rates of synthesis for plasma proteins.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci105812

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Wochner, R. D., Weissman, S. M., Waldmann, T. A., Houston, D., & Berlin, N. I.
Venue
Journal of Clinical Investigation
Published
1968-05-01
Volume
47
Issue
5
Pages
971-982
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2018938367
Cited by
69
References
0
FWCI
10.40
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.