Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 469

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Ionized calcium in normal serum, ultrafiltrates, and whole blood determined by ion-exchange electrodes

Open access
Moore, Edward W.·1970·Journal of Clinical Investigation

Abstract

Ion-exchange calcium electrodes represent the first practical method for the direct measurement of ionized calcium [Ca(++)] in biologic fluids. Using both "static" and "flow-through" electrodes, serum [Ca(++)] was within a rather narrow range: 0.94-1.33 mmoles/liter (mean, 1.14 mmoles/liter). Within a given individual, [Ca(++)] varied only about 6% over a several month period. Consistent pH effects on [Ca(++)] were observed in serum and whole blood, [Ca(++)] varying inversely with pH. Less consistent pH effects were also noted in ultrafiltrates, believed to largely represent precipitation of certain calcium complexes from a supersaturated solution. Heparinized whole blood [Ca(++)] was significantly less than in corresponding serum at normal blood pH, related to the formation of a calcium-heparin complex. [Ca(++)] in ultrafiltrates represented a variable fraction (66.7-90.2%) of total diffusible calcium. There was no apparent correlation between serum ionized and total calcium concentrations. Thus, neither serum total calcium nor total ultrafiltrable calcium provided a reliable index of serum [Ca(++)]. Change in serum total calcium was almost totally accounted for by corresponding change in protein-bound calcium [CaProt]. About 81% of [CaProt] was estimated to be bound to albumin and about 19% to globulins. From observed pH, serum protein, and [CaProt] data, a nomogram was developed for estimating [CaProt] without ultrafiltration. Data presented elsewhere indicate that calcium binding by serum proteins obeys the mass-law equation for a monoligand association. This was indicated in the present studies by a close correspondence of observed serum [Ca(++)] values with those predicted by the McLean-Hastings nomogram. While these electrodes allow study of numerous problems not possible previously, they have not been perfected to the same degree of reliability obtainable with current pH electrodes. The commercial (Orion flow-through) electrode is: (a) expensive. (b) requires periodic replacement of membranes, and (c) has not yet been thermostated. As with blood pH measurements. (d) electrode response is logarithmic, i.e. small potential errors generate rather large [Ca(++)] errors. (e) loss of CO(2) should be prevented, and (f) errors due to other cations must be considered under certain conditions. Despite these limitations, we believe the electrode represents a major advance in calcium metabolism.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci106241

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 469

Metadata

Authors
Moore, E. W.
Venue
Journal of Clinical Investigation
Published
1970-02-01
Volume
49
Issue
2
Pages
318-334
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2122136617
Cited by
469
References
17
FWCI
22.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ionized calcium in normal serum, ultrafiltrates, and whole blood determined by ion-exchange electrodes. https://app.cochat.ai/papers/10.1172/jci106241
The paper
Moore, E. W. (1970). Ionized calcium in normal serum, ultrafiltrates, and whole blood determined by ion-exchange electrodes. Journal of Clinical Investigation. https://doi.org/10.1172/jci106241

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.