CoChat

Human serum proinsulin

Open access
Melani, F., Rubenstein, A. H., Steiner, D. F. · 1970 · Journal of Clinical Investigation
Cited by 104

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Gel filtration of human serum extracts on Bio-Gel P-30 columns produced two peaks of material reactive with insulin antisera. The earlier eluting fraction appeared at the elution position of proinsulin (serum proinsulin-like component, PLC) while the second fraction corresponded in elution volume to insulin. In assays using porcine insulin-(131)I and an antiserum against porcine insulin, human pancreatic proinsulin was less reactive than human insulin. Serial dilutions of the serum PLC in the immunoassay showed immunological identity with the human proinsulin standard. Partial tryptic digestion of the serum PLC yielded products with increased immunological reactivity as estimated with insulin as the standard. With larger amounts of trypsin, all the serum PLC was converted to insulin-like components (desthreonine and desoctapeptide insulin). On the basis of these results we conclude that the earlier eluting fraction of human serum extracts is proinsulin. The fasting values of proinsulin in normal subjects ranged between 0.05 and 0.4 ng/ml, representing from 5 to 48% of the insulin concentration. In one subject the values of proinsulin were higher than those of insulin. After oral administration of 100 g of glucose, the proinsulin levels tended to rise similarly to insulin. Three obese patients with hyperinsulinemia had higher fasting levels of proinsulin and a greater increase after glucose than the normal subjects. As the high levels of proinsulin coexisted with raised insulin concentration in these obese subjects, the relative proportions of the two hormones were in the same range observed in the normal group. Thus hyperinsulinemia in these obese subjects was not accompanied by an increase in the fraction of serum proinsulin. When the values for serum proinsulin were expressed as percentage of the insulin levels, there was a decrease in the per cent proinsulin in the first hour of the glucose tolerance test. After the second hour, the per cent tended to rise towards the fasting levels.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1172/jci106259

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 104

Metadata

Authors
Melani, F., Rubenstein, A. H., & Steiner, D. F.
Venue
Journal of Clinical Investigation
Published
1970-03-01
Volume
49
Issue
3
Pages
497-507
ISSN
0021-9738 (ISSN-L)
OpenAlex
W2077413095
Cited by
104
References
1
FWCI
46.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Human serum proinsulin. https://app.cochat.ai/papers/10.1172/jci106259
The paper
Melani, F., Rubenstein, A. H., & Steiner, D. F. (1970). Human serum proinsulin. Journal of Clinical Investigation. https://doi.org/10.1172/jci106259

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.