The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
A Radioimmunoassay for Measurement of 3,3′, 5′-Triiodothyronine (Reverse T3)
Open accessAbstract
A highly specific antiserum to 3,3',5'-triiodothyronine (reverse T(3), rT(3)) was prepared by immunization of rabbits with D,L-rT(3)-human serum albumin conjugate. Of the various thyroid hormone derivatives tested, only 3,3'-diiodothyronine (3,3'-T(2)) cross-reacted significantly (10%) with rT(3)-binding sites on the antiserum, while thyroxine (T(4)) and triiodothyronine (T(3)) cross-reacted by less than 0.1%. The antiserum was used in a simple, sensitive, precise, and reproducible radioimmunoassay (RIA) for measurement of rT(3) in ethanolic extracts of serum. The dose-response curves of inhibition of the binding of [(125)I]rT(3) to antibody obtained by serial dilutions of serum extracts were essentially parallel to the standard assay curve. Recovery of nonradioactive rT(3) added to serum before extraction averaged 93%. Serum rT(3) concentrations were found to be (mean+/-SD) 41+/-10 ng/100 ml in 27 normal subjects, 103+/-49 ng/100 ml in 22 hyperthyroid patients, 19+/-9 ng/100 ml in 12 hypothyroid patients, and 54+/-7 ng/100 ml in five subjects with elevated serum thyroxine-binding globulin: the values in each of the latter three groups of individuals were significantly different from normal. Reverse T(3) was detected regularly in normal or supranormal concentrations in serum of 12 hypothyroid patients rendered euthyroid or mildly hyperthyroid by treatment with synthetic T(4). It is suggested that serum rT(3) values noted here should be taken to reflect the relative changes in serum rT(3) rather than its absolute values in health and thyroid disease. True serum rT(3) may be somewhat different because: (a) D.L-rT(3) employed in the standard curve and L-rT(3) present in human serum may react differently with anti-D,L-rT(2). (b) Even though 3,3'-T(2), which cross-reacted 10% in rT(3) RIA, has been considered unlikely to be present in human serum, it may circulate in low levels. (c) Cross-reaction of T(4) in rT(3) RIA of 0.06% although small, could contribute to RIA estimates of rT(2); the effect of T(4) would be particularly important in case of serum of hyperthyroid patients. Thus, serum rT(3) concentration in hyperthyroid patients averaged 89+/-48 mug/100 ml after correction for cross-reaction effects of T(4): this value was about 14% lower than that before correction (see above). Serum rT(3) concentration in cord sera of seven newborns averaged 136+/-19 ng/100 ml; it was clearly elevated and within the range of values seen in hyperthyroid patients. This was the case when the mean T(4) concentration in the newborn cord sera was moderately higher than normal and about one-half that in hyperthyroid patients, whereas serum T(3) was markedly below the normal adult level. A Pronase hydrolysate of thyroglobulin prepared from pooled normal thyroid glands contained 0.042, 3.0, and 0.16 mug/mg protein of rT(3), T(4), and T(3), respectively. The various data suggest that: (a) rT(3) is a normal component of human serum and thyroglobulin: (b) peripheral metabolism of T(4) is an important source of the rT(3) present in serum: (c) peripheral conversion of T(4) to T(3) and rT(3) may not necessarily be a random process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Radioimmunoassay for Measurement of Thyroxine in Unextracted Serum*
CHOPRA, I. J. (1972) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-34-6-938 · Cited by 539
Self-citationConversion of Thyroxine (T4) to triiodothyronine (T3) in athyreotic human subjects
Braverman, L. E., Ingbar, S. H., & Sterling, K. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106304 · Cited by 485
Propylthiouracil inhibits the conversion of l-thyroxine to l-triiodothyronine
Oppenheimer, J. H., Schwartz, H. L., & Surks, M. I. (1972) · Journal of Clinical Investigation · doi:10.1172/jci107063 · Cited by 258
Surks, M. I., Schadlow, A. R., Stock, J. M., & Oppenheimer, J. H. (1973) · Journal of Clinical Investigation · doi:10.1172/jci107244 · Cited by 223
Triiodothyronine Radioimmunoassay
Lieblich, J., & Utiger, R. D. (1972) · Journal of Clinical Investigation · doi:10.1172/jci106786 · Cited by 128
Radioimmunassay for measurement of triiodothyronine in human serum
Chopra, I. J., Solomon, D. H., & Beall, G. N. (1971) · Journal of Clinical Investigation · doi:10.1172/jci106696 · Cited by 119
Self-citation
Cited by
The Deiodinase Family of Selenoproteins
GERMAIN, D. L. S., & GALTON, V. A. (1997) · Thyroid · doi:10.1089/thy.1997.7.655 · Cited by 342
EFFECT OF CALORIC RESTRICTION AND DIETARY COMPOSITION ON SERUM T3AND REVERSE T3IN MAN
Spaulding, S. W., Chopra, I. J., Sherwin, R. S., & Lyall, S. S. (1976) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-42-1-197 · Cited by 278
Self-citationLaurberg, P. (1984) · Metabolism · doi:10.1016/0026-0495(84)90203-8 · Cited by 84
The colorful diversity of thyroid hormone metabolites
Köhrle, J. (2019) · European Thyroid Journal · doi:10.1159/000497141 · Cited by 67
BURMAN, K. D., DIMOND, R. C., WRIGHT, F. D., EARLL, J. M., BRUTON, J., & WARTOFSKY, L. (1977) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-44-4-660 · Cited by 53
Metadata
- Authors
- Chopra, I. J.
- Venue
- Journal of Clinical Investigation
- Published
- 1974-09-01
- Volume
- 54
- Issue
- 3
- Pages
- 583-592
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2003019021
- Cited by
- 251
- References
- 6
- FWCI
- 24.84
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Radioimmunoassay for Measurement of 3,3′, 5′-Triiodothyronine (Reverse T3). https://app.cochat.ai/papers/10.1172/jci107795
- The paper
- Chopra, I. J. (1974). A Radioimmunoassay for Measurement of 3,3′, 5′-Triiodothyronine (Reverse T3). Journal of Clinical Investigation. https://doi.org/10.1172/jci107795
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.