The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Hemodynamic determinants of the time-course of fall in canine left ventricular pressure.
Open accessAbstract
The hemodynamic determinants of the time-course of fall in isovolumic left ventricular pressure were assessed in isolated canine left ventricular preparations. Pressure fall was studied in isovolumic beats or during prolonged isovolumic diastole after ejection. Pressure fall was studied in isovolumic relaxation for isovolumic and ejecting beats (r less than or equal to 0.98) and was therefore characterized by a time constant, T. Higher heart rates shortened T slightly from 52.6 +/- 4.5 ms at 110/min to 48.2 +/- 6.0 ms at 160/min (P less than 0.01, n = 8). Higher ventricular volumes under isovolumic conditions resulted in higher peak left ventricular pressure but no significant change in T. T did shorten from 67.1 +/- 5.0 ms in isovolumic beats to 45.8 +/- 2.9 ms in the ejecting beats (P less than 0.001, n = 14). In the ejecting beats, peak systolic pressure was lower, and end-systolic volume smaller. To differentiate the effects of systolic shortening during ejection from those of lower systolic pressure and smaller end-systolic volume, beats with large end-diastolic volumes were compared to beats with smaller end-diastolic volumes. The beats with smaller end-diastolic volumes exhibited less shortening but similar end-systolic volumes and peak systolic pressure. T again shortened to a greater extent in the beats with greater systolic shortening. Calcium chloride and acetylstrophanthidin resulted in no significant change in T, but norepinephrine, which accelerates active relaxation, resulted in a significant shortening of T (65.6 +/- 13.4 vs. 46.3 +/- 7.0 ms, P less than 0.02). During recovery from ischemia, T increased significantly from 59.3 +/- 9.6 to 76.8 +/- 13.1 ms when compared with the preischemic control beat (P less than 0.05). Thus, the present studies show that the time-course of isovolumic pressure fall subsequent to maximum negative dP/dt is exponential, independent of systolic stress and end-systolic fiber length, and minimally dependent on heart rate. T may be an index of the activity of the active cardiac relaxing system and appears dependent on systolic fiber shortening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Mathematical Functions with Formulas, Graphs, and Mathematical Tables
W., J. W., Abramowitz, M., & Stegun, I. A. (1965) · Mathematics of Computation · doi:10.2307/2004114 · Cited by 18,663
Buccino, R. A., Spann, J. F., Pool, P. E., Sonnenblick, E. H., & Braunwald, E. (1967) · Journal of Clinical Investigation · doi:10.1172/jci105658 · Cited by 384
Diminished inotropic response of aged myocardium to catecholamines.
Lakatta, E. G., Gerstenblith, G., Angell, C. S., Shock, N. W., & Weisfeldt, M. L. (1975) · Circulation Research · doi:10.1161/01.res.36.2.262 · Cited by 331
Self-citationAshley, C., & Ridgway, E. B. (1969) · PubMed · Cited by 325
The mechanical properties of relaxing muscle
Jewell, B. R., & Wilkie, D. R. (1960) · The Journal of Physiology · doi:10.1113/jphysiol.1960.sp006467 · Cited by 322
Mechanical Properties of Rat Cardiac Muscle during Experimental Hypertrophy
BING, O. H. L., MATSUSHITA, S., FANBURG, B. L., & LEVINE, H. J. (1971) · Circulation Research · doi:10.1161/01.res.28.2.234 · Cited by 287
Myocardial sarcomere dynamics during isometric contraction.
Krueger, J. W., & Pollack, G. H. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011112 · Cited by 182
Frequency-force relationships of mammalian ventricular muscle in vivo and in vitro
Kahn, M., Kavaler, F., & Fisher, V. (1976) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1976.230.3.631 · Cited by 18
Cited by
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Appleton, C. P., Hatle, L. K., & Popp, R. L. (1988) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(88)90416-0 · Cited by 1,568
Zile, M. R., Baicu, C. F., & Gaasch, W. H. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032566 · Cited by 1,563
Sohn, D.-W., Chai, I.-H., Lee, D.-J., Kim, H.-C., Kim, H.-S., Oh, B.-H., Lee, M.-M., Park, Y.-B., Choi, Y.-S., Seo, J.-D., et al. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)88335-0 · Cited by 1,557
Zile, M. R., & Brutsaert, D. L. (2002) · Circulation · doi:10.1161/hc1102.105289 · Cited by 1,184
Metadata
- Authors
- Weiss, J. L., Frederiksen, J. W., & Weisfeldt, M. L.
- Venue
- Journal of Clinical Investigation
- Published
- 1976-09-01
- Volume
- 58
- Issue
- 3
- Pages
- 751-760
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2091360003
- Cited by
- 1,077
- References
- 8
- FWCI
- 5.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.