The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Ventilation-perfusion inequality in chronic obstructive pulmonary disease.
Open accessAbstract
A multiple inert gas elimination method was used to study the mechanism of impaired gas exchange in 23 patients with advanced chronic obstructive pulmonary disease (COPD). Three patterns of ventilation-perfusion (Va/Q) inequality were found: (a) A pattern with considerable regions of high (greater than 3) VA/Q, none of low (less than 0.1) VA/Q, and essentially no shunt. Almost all patients with type A COPD showed this pattern, and it was also seen in some patients with type B. (b) A pattern with large amounts of low but almost none of high VA/Q, and essentially no shunt. This pattern was found in 4 of 12 type B patients and 1 of type A. (c) A pattern with both low and high VA/Q areas was found in the remaining 6 patients. Distributions with high VA/Q areas occurred mostly in patients with greatly increased compliance and may represent loss of blood-glow due to alveolar wall destruction. Similarly, well-defined modes of low VA/Q areas were seen mostly in patients with severe cough and sputum and may be due to reduced ventilation secondary to mechanical airways obstruction or distortion. There was little change in the VA/Q distributions on exercise or on breathing 100% O2. The observed patterns of VA/Q inequality and shunt accounted for all of the hypoxemia at rest and during exercise. There was therefore no evidence for hypoxemia caused by diffusion impairment. Patients with similar arterial blood gases often had dissimilar VA/Q patterns. As a consequence the pattern of VA/Q inequality could not necessarily be inferred from the arterial PO2 and PCO2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solving Least Squares Problems
Lawson, C. L., & Hanson, R. J. (1995) · doi:10.1137/1.9781611971217 · Cited by 7,103
Wagner, P. D., Laravuso, R. B., Uhi, R. R., & West, J. B. (1974) · Journal of Clinical Investigation · doi:10.1172/jci107750 · Cited by 479
Self-citationSimultaneous measurement of eight foreign gases in blood by gas chromatography
Wagner, P. D., Naumann, P. F., & Laravuso, R. B. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.36.5.600 · Cited by 360
Self-citationTHE EMPHYSEMATOUS AND BRONCHIAL TYPES OF CHRONIC AIRWAYS OBSTRUCTION
Burrows, B., Fletcher, C. M., Heard, B. E., Jones, N. L., & Wootliff, J. S. (1966) · The Lancet · doi:10.1016/s0140-6736(66)90181-4 · Cited by 347
Ventilation-perfusion inequality and overall gas exchange in computer models of the lung
West, J. B. (1969) · Respiration Physiology · doi:10.1016/0034-5687(69)90071-1 · Cited by 307
Self-citationElimination of inert gas by the lung
Farhi, L. E. (1967) · Respiration Physiology · doi:10.1016/0034-5687(67)90018-7 · Cited by 197
Relation between anatomic respiratory dead space and body size and lung volume
Hart, M. C., ORZALESI, M. M., & Cook, C. D. (1963) · Journal of Applied Physiology · doi:10.1152/jappl.1963.18.3.519 · Cited by 136
Effects of diffusion impairment on O 2 and CO 2 time courses in pulmonary capillaries.
Wagner, P. D., & West, J. B. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.33.1.62 · Cited by 105
Self-citationThe uptake of carbon monoxide in health and in emphysema.
Dv, B. (1952) · PubMed · Cited by 61
Cited by
Siafakas, N., Vermeire, P., Pride, N., Paoletti, P., Gibson, J., Howard, P., Yernault, J., Decramer, M., Higenbottam, T., Postma, D., et al. (1995) · European Respiratory Journal · doi:10.1183/09031936.95.08081398 · Cited by 1,592
Hypoxic Pulmonary Vasoconstriction
Sylvester, J. T., Shimoda, L. A., Aaronson, P. I., & Ward, J. P. T. (2012) · Physiological Reviews · doi:10.1152/physrev.00041.2010 · Cited by 725
Poole, D. C., & Jones, A. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100072 · Cited by 514
Hypoxemia in patients with COPD: cause, effects, and disease progression
McNicholas, W., Kent, & Mitchell (2011) · International Journal of Chronic Obstructive Pulmonary Disease · doi:10.2147/copd.s10611 · Cited by 434
Aubier, M., Murciano, D., Milic-Emili, J., Touaty, E., Daghfous, J., Pariente, R., & Derenne, J. P. (1980) · American Review of Respiratory Disease · doi:10.1164/arrd.1980.122.5.747 · Cited by 431
Metadata
- Authors
- Wagner, P. D., Dantzker, D. R., Dueck, R., Clausen, J. L., & West, J. B.
- Venue
- Journal of Clinical Investigation
- Published
- 1977-02-01
- Volume
- 59
- Issue
- 2
- Pages
- 203-216
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2133936382
- Cited by
- 445
- References
- 9
- FWCI
- 12.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.