The DOI matches its Crossref record.
Atrial natriuretic factor in human blood.
Open accessAbstract
To determine whether atrial natriuretic factor (ANF) is a circulating hormone in men, a radioimmunoassay suitable for the estimation of ANF in human plasma was developed and the nature of plasma ANF was characterized. Plasma ANF was extracted before radioimmunoassay by affinity chromatography on a column of ANF antibody-coupled agarose. When plasma ANF extract was analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis, with the radioimmunoassay of the eluted gel slices for ANF, almost all of the ANF activities ran in the 3,000-mol-wt area, while three peaks of ANF were observed in human atrial tissue extract, molecular weights of which corresponded to 14,000, 6,000, and 3,000, respectively. Reversed-phase high performance liquid chromatography of atrial tissue extract resolved multiple forms of ANF. In contrast, one major peak was observed in human plasma extract, and its retention time coincided with that of synthetic human alpha-atrial natriuretic polypeptide. When 500 ml of 0.9% saline was infused into six healthy subjects over 45 min, plasma levels of ANF were unequivocally elevated. The mean plasma ANF concentrations rose from the baseline (23.0 +/- 2.5 pg/ml, mean +/- SEM, n = 6) to the peak (41.8 +/- 4.9 pg/ml, mean +/- SEM) at 75 min postinfusion. No significant change in plasma ANF, on the other hand, was found in the control group. These results suggest that ANF is a circulating hormone in men and is secreted in response to isotonic volume expansion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Rational Approach to Perioperative Fluid Management
Chappell, D., Jacob, M., Hofmann-Kiefer, K., Conzen, P., & Rehm, M. (2008) · Anesthesiology · doi:10.1097/aln.0b013e3181863117 · Cited by 909
Pathophysiology and clinical implications of perioperative fluid excess
Holte, K., Sharrock, N. E., & Kehlet, H. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/aef220 · Cited by 634
Epstein, F. H., Epstein, F. H., Needleman, P., & Greenwald, J. E. (1986) · New England Journal of Medicine · doi:10.1056/nejm198603273141306 · Cited by 484
Ishimitsu, T., Nishikimi, T., Saito, Y., Kitamura, K., Eto, T., Kangawa, K., Matsuo, H., Omae, T., & Matsuoka, H. (1994) · Journal of Clinical Investigation · doi:10.1172/jci117573 · Cited by 475
Saito, Y., Nakao, K., Nishimura, K., Sugawara, A., Okumura, K., Obata, K., Sonoda, R., Ban, T., Yasue, H., & Imura, H. (1987) · Circulation · doi:10.1161/01.cir.76.1.115 · Cited by 347
Sodium loading and posture modulate human atrial natriuretic factor plasma levels.
Hollister, A. S., Tanaka, I., Imada, T., Onrot, J., Biaggioni, I., Robertson, D., & Inagami, T. (1986) · Hypertension · doi:10.1161/01.hyp.8.6_pt_2.ii106 · Cited by 340
PLASMA ENDOTHELIN LEVELS IN PATIENTS WITH URAEMIA
Koyama, H., Nishzawa, Y., Morii, H., Tabata, T., Inoue, T., & Yamaji, T. (1989) · The Lancet · doi:10.1016/s0140-6736(89)92631-7 · Cited by 286
Self-citationNishikimi, T., Yoshihara, F., Morimoto, A., Ishikawa, K., Ishimitsu, T., Saito, Y., Kangawa, K., Matsuo, H., Omae, T., & Matsuoka, H. (1996) · Hypertension · doi:10.1161/01.hyp.28.1.22 · Cited by 261
Engler, D., Redei, E., & Kola, I. (1999) · Endocrine Reviews · doi:10.1210/edrv.20.4.0376 · Cited by 79
Jacob, M., Chappell, D., Hofmann-Kiefer, K., Conzen, P., Peter, K., & Rehm, M. (2007) · Der Anaesthesist · doi:10.1007/s00101-007-1235-4 · Cited by 51
Metadata
- Authors
- Yamaji, T., Ishibashi, M., & Takaku, F.
- Venue
- Journal of Clinical Investigation
- Published
- 1985-10-01
- Volume
- 76
- Issue
- 4
- Pages
- 1705-1709
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2063413405
- Cited by
- 247
- References
- 0
- FWCI
- 63.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.