Isovolumetric regulation of isolated S2 proximal tubules in anisotonic media.
Open accessThe DOI matches its Crossref record.
Abstract
Sudden alteration in medium osmolality causes an osmometric change in proximal tubule cell size followed by restoration of cell volume toward normal in hypotonic but not in hypertonic medium. We determined the capability of isolated nonperfused proximal tubules to prevent a change in cell volume in anisotonic media. The external osmolality was gradually changed over a range from 110 to 480 mosM. At 1.5 mosM/min, cell volume remained constant between 167 +/- 9 and 361 +/- 7 mosM, a phenomenon termed isovolumetric regulation (IVR). Cells lost intracellular solutes in hypotonic and gained intracellular solutes in hypertonic media. Raffinose or choline chloride substitution showed that osmolality, rather than NaCl, signalled cell volume maintenance in hyperosmotic media. Cooling (7-10 degrees C) blocked IVR. IVR was maintained when osmolality was lowered at a rate of 27, but not at 42 mosM/min. IVR was not observed when the rate of osmolality increase exceeded 3 mosM/min. We conclude that proximal tubule cells sensitively regulate intracellular volume in an osmolality range of pathophysiologic interest by mechanisms dependent on the rate of net water movement across basolateral membranes and the absolute intracellular content of critical solutes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Physiology of cell volume regulation in vertebrates
Hoffmann, E. K., Lambert, I. H., & Pedersen, S. F. (2009) · Physiological Reviews · doi:10.1152/physrev.00037.2007 · Cited by 1,441
Cellular Response to Hyperosmotic Stresses
Burg, M. B., Ferraris, J. D., & Dmitrieva, N. I. (2007) · Physiological Reviews · doi:10.1152/physrev.00056.2006 · Cited by 797
Membrane Mechanisms and Intracellular Signalling in Cell Volume Regulation
(1995) · International Review of Cytology · doi:10.1016/s0074-7696(08)62498-5 · Cited by 469
Regulation of Cell Volume in Health and Disease
McManus, M. L., Churchwell, K. B., & Strange, K. (1995) · New England Journal of Medicine · doi:10.1056/nejm199511093331906 · Cited by 441
Anisosmotic cell volume regulation: a comparative view
Chamberlin, M. E., & Strange, K. (1989) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1989.257.2.c159 · Cited by 395
Properties of volume-regulated anion channels in mammalian cells
Nilius, B., Eggermont, J., Voets, T., Buyse, G., Manolopoulos, V., & Droogmans, G. (1997) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(97)00021-7 · Cited by 360
Activation of ion transport pathways by changes in cell volume
Sarkadi, B., & Parker, J. C. (1991) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(91)90005-h · Cited by 302
Strange, K. (2004) · Advances in Physiology Education · doi:10.1152/advan.00034.2004 · Cited by 255
Physiological significance of volume-regulatory transporters
O’Neill, W. C. (1999) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1999.276.5.c995 · Cited by 245
“5 mosM/min, whereas the cells behaved as perfect osmometers at 3 mosM/min (104).”
BackgroundCserr, H. F., DePasquale, M., Nicholson, C., Patlak, C. S., Pettigrew, K. D., & Rice, M. E. (1991) · The Journal of Physiology · doi:10.1113/jphysiol.1991.sp018793 · Cited by 141
Metadata
- Authors
- Lohr, J. W., & Grantham, J. J.
- Venue
- Journal of Clinical Investigation
- Published
- 1986-11-01
- Volume
- 78
- Issue
- 5
- Pages
- 1165-1172
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2063199566
- Cited by
- 125
- References
- 0
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.