The DOI matches its Crossref record.
Effect of ultrasound on transdermal drug delivery to rats and guinea pigs.
Open accessAbstract
The effect of therapeutic range ultrasound (1 MHz) on skin permeation of D-mannitol, a highly polar sugar alcohol, inulin, a high molecular weight polysaccharide and physostigmine, a lipophilic anticholinesterase drug was studied in rats and guinea pigs. D-Mannitol and inulin are totally and rapidly excreted, once they have penetrated through the skin into the blood stream, permitting direct in vivo monitoring. For evaluating skin penetration of physostigmine the decrease of whole blood cholinesterase was measured. Ultrasound nearly completely eliminated the lag time usually associated with transdermal delivery of drugs. 3-5 min of ultrasound irradiation (1.5 W/cm2 continuous wave or 3 W/cm2 pulsed wave) increased the transdermal permeation of inulin and mannitol in rats by 5-20-fold within 1-2 h following ultrasound application. Ultrasound treatment also significantly increased (P less than 0.05) the inhibition of cholinesterase during the first hour after application in both physostigmine treated rats and guinea pigs: while in control guinea pigs no significant inhibition of cholinesterase could be detected during the first 2 h after application of physostigmine, the ultrasound treated group showed a 15 +/- 5% (mean +/- SEM) decrease in blood cholinesterase 1 h after ultrasound application. For physostigmine-treated rats the level of cholinesterase inhibition 1 h after ultrasound application was 53 +/- 5% in the ultrasound-treated group and 35 +/- 5% in the controls.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Langer, R. (1990) · Science · doi:10.1126/science.2218494 · Cited by 1,778
Self-citationBiomaterials in Drug Delivery and Tissue Engineering: One Laboratory's Experience
Langer, R. (2000) · Accounts of Chemical Research · doi:10.1021/ar9800993 · Cited by 750
Self-citationUltrasonic drug delivery – a general review
Pitt, W. G., Husseini, G. A., & Staples, B. J. (2004) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.1.1.37 · Cited by 621
Pulsatile drug release control using hydrogels
Kikuchi, A., & Okano, T. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00243-5 · Cited by 600
Ultrasound-mediated transdermal drug delivery: Mechanisms, scope, and emerging trends
Polat, B. E., Hart, D., Langer, R., & Blankschtein, D. (2011) · Journal of Controlled Release · doi:10.1016/j.jconrel.2011.01.006 · Cited by 447
Self-citation
Metadata
- Authors
- Levy, D., Kost, J., Meshulam, Y., & Langer, R.
- Venue
- Journal of Clinical Investigation
- Published
- 1989-06-01
- Volume
- 83
- Issue
- 6
- Pages
- 2074-2078
- ISSN
- 0021-9738 (ISSN-L)
- OpenAlex
- W2083334221
- Cited by
- 164
- References
- 0
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of ultrasound on transdermal drug delivery to rats and guinea pigs. https://app.cochat.ai/papers/10.1172/jci114119
- The paper
- Levy, D., Kost, J., Meshulam, Y., & Langer, R. (1989). Effect of ultrasound on transdermal drug delivery to rats and guinea pigs. Journal of Clinical Investigation. https://doi.org/10.1172/jci114119
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.